Sleep & breathing = Schlaf & Atmung
-
To assess the accuracy of a single channel portable monitoring device (RUSleepingtrade mark RTS, Respironics, Murrysville, PA) that measures nasal pressure (a surrogate for airflow) to detect sleep disordered breathing (SDB). Twenty-five adult patients referred to a community sleep laboratory with suspected obstructive sleep apnea (OSA) participated in this investigation. The portable monitoring device was used in the sleep laboratory to acquire data concurrently with a standard multi-channel polysomnogram (PSG) to assess SDB. ⋯ Similar results were observed for detecting moderate-severe SDB (PSG AHI > or = 15 events h(-1)) using REI >15.2 events h(-1). In a population of subjects with suspected OSA, this portable monitoring device can automatically quantify an REI that compares well to the AHI scored manually on a concurrent PSG. Such a device may prove useful to assess SDB in high risk populations with self-administered testing in ambulatory settings such as the home.
-
Randomized Controlled Trial Comparative Study
Effects of nasal mask leak and heated humidification on nasal mucosa in the therapy with nasal continuous positive airway pressure (nCPAP).
The purpose of this study was to determine the objective short-term influence of nasal continuous positive airway pressure (nCPAP) therapy, nasal mask leak (NML) and heated humidifiers (HH) to nasal conditioning of spontaneously breathing subjects. This was a prospective, non-randomized, non-blinded day-time study. Eighteen healthy subjects were enrolled in the study. ⋯ No difference was found between aH (nCPAP and HH) and aH (nCPAP alone). Airway temperature did not change significantly after application of nCPAP alone, nCPAP and NML, and nCPAP and HH. These data indicate that nCPAP therapy with NML tends to have more remarkable reduction of the nasal humidity than nCPAP therapy without NML. nCPAP with heated humidifier is able to compensate the dehydration effects induced by nCPAP therapy with NML by increasing the aH at the anterior turbinate area to the levels observed during breathing with nCPAP alone.
-
Asthma has been identified as a possible risk factor for Obstructive Sleep Apnea (OSA) in children. It is not known whether parent-reported asthma increases the likelihood of the diagnosis of OSA in snoring children. We hypothesized that snoring children with asthma are more likely to have OSA than snoring children without asthma. ⋯ We found no increased risk for polysomnographically diagnosed OSA for asthmatics. To the contrary, by logistic regression analysis, a parent/guardian report of asthma decreased the odds of having OSA by 34% (p = 0.027), controlling for individual and socioeconomic factors and assessment results. Polysomnographic (PSG) differences between asthmatic and non-asthmatic children were found in only the arousal index (11.0 vs.9.3 +/- 6.5/h, p = 0.099) and total sleep time (337.1 +/- 64.3 vs. 347 +/- 65.2 min, p = 0.1) In a referral-based group of predominantly AA inner-city snoring children, asymptomatic asthma decreased the likelihood of OSA.
-
Obstructive sleep apnea (OSA) is associated with cardiovascular diseases, yet available data suggests cardiologists underreport OSA. This study assessed whether cardiologists' knowledge and attitudes about OSA contribute to this finding. A previously validated questionnaire, the "Obstructive Sleep Apnea Knowledge and Attitudes Questionnaire" (OSAKA), was modified by the addition of 20 knowledge items and one attitude question to include a total of 38 knowledge items and six attitude questions. ⋯ Total knowledge scores correlated with attitude scores (r = 0.29, p = 0.004). Cardiologists' knowledge about OSA is comparable to that of PCPs. Cardiologists may lack confidence identifying and managing patients with OSA, factors that may contribute to their low rate of reporting OSA.