Regional anesthesia and pain medicine
-
Reg Anesth Pain Med · Sep 2013
Compound imaging technology and echogenic needle design: effects on needle visibility and tissue imaging.
Needle visualization in ultrasound-guided regional anesthesia can be improved by using needles of echogenic design with higher rate of reflection of ultrasound waves. Imaging solutions such as compound imaging might further improve imaging of both needle and tissue; these effects have not yet been studied. We hypothesized that compound imaging would significantly improve needle visibility, regardless of the insertion angle or needle type used. The effects of compound imaging on needle artifacts and tissue imaging were also investigated. ⋯ Compound imaging technology enhances needle imaging with both echogenic and conventional needles. Tissue imaging and speckle artifacts are also optimized. Echogenic needle design results in better needle visibility scores in both B-mode and compound imaging.
-
Reg Anesth Pain Med · Sep 2013
Biography Historical ArticleReconceptualizing John F. Kennedy's Chronic Low Back Pain.
When the medical records for John Fitzgerald Kennedy were made public, it became clear that the 35th President of the United States suffered greatly from a series of medical illnesses from the time he was a toddler until his assassination in November of 1963. Aside from having Addison disease, no condition seemed to cause him more distress than did his chronic low back pain. ⋯ Herein, the mechanisms underlying his pain are evaluated based on more contemporary pain research. This reconceptualizing of John Fitzgerald Kennedy's pain could serve as a model for other cases where the main cause of the pain is presumed to be located in the periphery.
-
Reg Anesth Pain Med · Sep 2013
Randomized Controlled TrialEffect of Chronic β-Blockade on the Utility of an Epinephrine-Containing Test Dose to Detect Intravascular Injection in Nonsedated Patients.
A test dose containing epinephrine is routinely used during epidural blockade to detect accidental intravenous needle or catheter placement before the administration of local anesthetics to avert local anesthetic systemic toxicity. β-Blocker therapy may interfere with the expected hemodynamic response from an intravascular injection. This study describes a cohort of 24 patients and their response to an epinephrine test dose (ie, if expected increased heart rates during test-dose administration are valid in this population.) ⋯ Epinephrine test-dose administration in nonsedated, chronically β-blocked patients cannot distinguish intravenous injection at the classic threshold increase of 20 bpm. The response in individuals is varied, and thresholds for a positive test need revising for this population of patients on therapeutic β-blockers.