Regional anesthesia and pain medicine
-
Reg Anesth Pain Med · Dec 2021
Randomized Controlled TrialRandomized trial comparing the spread of erector spinae block with the combination of erector spinae block and retrolaminar block in soft embalmed Thiel cadavers.
Erector spinae plane (ESP) and retrolaminar (RL) blocks show unreliable spread. We hypothesize that the combination of ESP and RL blocks provides more extensive and reliable spread of dye than single ESP blocks. Our primary objective was to compare the spread of dye to the paravertebral spaces after the combination block and ESP block in Thiel embalmed cadavers. Spread, the primary end point, was defined as the number of paravertebral spaces colored with dye per injection. ⋯ In conclusion, the combination of ESP and RL blocks was more extensive and reliable than ESP block alone.