Sensor fusion using a hybrid median filter for artifact removal in intraoperative heart rate monitoring.
Intraoperative heart rate is routinely measured independently from the ECG monitor, pulse oximeter, and the invasive blood pressure monitor if available. The presence of artifacts, in one or more of theses signals, especially sustained artifacts, represents a critical challenge for physiological monitoring. When temporal filters are used to suppress sustained artifacts, unwanted delays or signal distortion are often introduced. The aim of this study was to remove artifacts and derive accurate estimates for the heart rate signal by using measurement redundancy. ⋯ The hybrid median filter combines the structural and temporal information from two or more sensors and generates a robust estimate of heart rate without requiring strict assumptions about the signal's characteristics. This method is intuitive, computationally simple, and the performance can be easily adjusted. These considerable benefits make this method highly suitable for clinical use.
-
J Clin Monit Comput · Apr 2009
Evaluation of a computerized system for mechanical ventilation of infants.
To evaluate a computerized system for mechanical ventilation of infants. ⋯ A computerized system for mechanical ventilation is evaluated for treatment of infants. The results of the study show that the system has good potential for use in neonatal ventilatory care. Further refinements can be made in the system for very low-birth-weight infants.
-
J Clin Monit Comput · Apr 2009
Comparative StudyFlow-through versus sidestream capnometry for detection of end tidal carbon dioxide in the sedated patient.
End tidal carbon dioxide (ETCO(2)) in non-intubated patients can be monitored using either sidestream or flow-through capnometry [Yamamori et al., J Clin Monit Comput 22(3):209-220, 2008]. The hypothesis of this validation study is that, flow-through capnometry will yield a more accurate estimate of ETCO(2) than sidestream capnometry when evaluated in a bench study during low tidal volumes and high oxygen administration via nasal cannula. Secondarily, when ETCO(2) from each is compared to arterial CO(2) (PaCO(2)) during a study in which healthy, non-intubated volunteers are tested under normocapnic, hypocapnic and hypercapnic conditions, the flow-through capnometer will resemble PaCO(2) more closely than the sidestream capnometer. This will be especially true during periods of lower minute ventilation and high oxygen flow rates via mask in non-intubated, remifentanil sedated, healthy volunteers whose physiologic deadspace is small. ⋯ Within a wide limit of agreement between the volunteer and bench study, flow-through and sidestream capnometry performed equally well during bench testing and in non-intubated, sedated patients.
-
J Clin Monit Comput · Apr 2009
Hypotension after spinal anesthesia for cesarean section: identification of risk factors using an anesthesia information management system.
To determine risk factors for developing hypotension after spinal anesthesia for cesarean section to prevent obstetric patients from hypotensive episodes potentially resulting in intrauterine malperfusion and endangering the child. ⋯ Knowledge of these risk factors should increase the anesthesiologist's attention to decide for the necessity to employ prophylactic or therapeutic techniques or drugs to prevent the neonate from any risk resulting of hypotension of the mother.