Journal of clinical monitoring and computing
-
J Clin Monit Comput · Jun 2016
A numerical model of blood oxygenation during veno-venous ECMO: analysis of the interplay between blood oxygenation and its delivery parameters.
Veno-venous extracorporeal membrane oxygenation (VV-ECMO) is an important tool in the management of most severe forms of acute respiratory failure. The determinants and management of oxygen delivery in patients treated with VV-ECMO is a complex topic. The physiological principles of oxygenation on VV-ECMO are reviewed in many textbooks. ⋯ The numerical analysis of variation and interplay between each oxygenation determinants during VV-ECMO is presented in graphical form. These results corroborate all the findings of previous studies. The proposed numerical model facilitates understanding of oxygenation physiology during VV-ECMO; it can be used for a medical simulation system and for teaching the principles of oxygenation during VV-ECMO.
-
J Clin Monit Comput · Jun 2016
Real time noninvasive estimation of work of breathing using facemask leak-corrected tidal volume during noninvasive pressure support: validation study.
We describe a real time, noninvasive method of estimating work of breathing (esophageal balloon not required) during noninvasive pressure support (PS) that uses an artificial neural network (ANN) combined with a leak correction (LC) algorithm, programmed to ignore asynchronous breaths, that corrects for differences in inhaled and exhaled tidal volume (VT) from facemask leaks (WOBANN,LC/min). Validation studies of WOBANN,LC/min were performed. Using a dedicated and popular noninvasive ventilation ventilator (V60, Philips), in vitro studies using PS (5 and 10 cm H2O) at various inspiratory flow rate demands were simulated with a lung model. ⋯ For the in vivo study, WOBANN,LC/min and WOBPHYS/min ranged from 3 to 12 J/min and there was an excellent relationship between WOBANN,LC/breath and WOBPHYS/breath, r = 0.93, r(2) = 0.86 (p < 0.01). An ANN combined with a facemask LC algorithm provides noninvasive and valid estimates of work of breathing during noninvasive PS. WOBANN,LC/min, automatically and continuously estimated, may be useful for assessing inspiratory muscle loads and guiding noninvasive PS settings as in a decision support system to appropriately unload inspiratory muscles.
-
J Clin Monit Comput · Jun 2016
Review Meta AnalysisAccuracy of pleth variability index to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis.
To systemically evaluate the accuracy of pleth variability index to predict fluid responsiveness in mechanically ventilated patients. A literature search of PUBMED, OVID, CBM, CNKI and Wanfang Data for clinical studies in which the accuracy of pleth variability index to predict fluid responsiveness was performed (last update 5 April 2015). Related journals were also searched manually. ⋯ No statistical differences were found between OR subgroup and ICU subgroup in the AUC [0.89 (95 % CI 0.85-0.92) versus 0.90 (95 % CI 0.82-0.94); P = 0.97], and in the specificity [0.84 (95 % CI 0.75-0.86) vs. 0.84 (95 % CI 0.75-0.91); P = 1.00]. Sensitivity was higher in the OR subgroup than the ICU subgroup [0.84 (95 % CI 0.78-0.88) vs. 0.56 (95 % CI 0.47-0.64); P = 0.00004]. The pleth variability index has a reasonable ability to predict fluid responsiveness.
-
J Clin Monit Comput · Jun 2016
Comparative StudyComparison of train-of-four ratios measured with Datex-Ohmeda's M-NMT MechanoSensor™ and M-NMT ElectroSensor™.
Neuromuscular blockade is usually monitored using train-of-four (TOF) stimulation pattern. A TOF ratio of higher than 90 % is recommended to reduce the risk of adverse effects after anaesthesia. TOF ratio 90 % is used in clinical practice with all different neuromuscular monitors. ⋯ After anaesthetic induction, but before administration of rocuronium, both TOF sensor values drifted from the TOF value of 1.0, showing either significant spontaneous fade (T1 > T4) or tendency of reverse fade (T1 < T4). KMG overestimates the recovery from neuromuscular blockade when compared with EMG. KMG and EMG cannot be used interchangeably, and TOF ratio 90 % cannot be considered as adequate level of recovery with all monitoring devices.
-
J Clin Monit Comput · Jun 2016
Intraoperative blood glucose management: impact of a real-time decision support system on adherence to institutional protocol.
Poor perioperative glycemic management can lead to negative surgical outcome. Improved compliance to glucose control protocol could lead to better glucose management. An Anesthesia Information Management System based decision support system-Smart Anesthesia Manager™ (SAM) was used to generate real-time reminders to the anesthesia providers to closely adhere to our institutional glucose management protocol. ⋯ Compliance to hourly glucose measurement and correct insulin doses increased significantly during the intervention period when compared with the baseline (from 52.6 to 71.2 % and from 13.5 to 24.4 %, respectively). In spite of improved compliance to institutional protocol, the mean glucose levels and other glycemic management parameters did not show significant improvement with SAM reminders. Real-time electronic reminders improved intraoperative compliance to institutional glucose management protocol though glycemic parameters did not improve even when there was greater compliance to the protocol.