Journal of clinical monitoring and computing
-
J Clin Monit Comput · Aug 2016
Safe transcranial electric stimulation motor evoked potential monitoring during posterior spinal fusion in two patients with cochlear implants.
Transcranial electric stimulation (TES) motor evoked potentials (MEPs) have become a regular part of intraoperative neurophysiologic monitoring (IONM) for posterior spinal fusion (PSF) surgery. Almost all of the relative contraindications to TES have come and gone. ⋯ Herein we illustrate two cases of pediatric patients with CIs who underwent PSF using TES MEPs as part of IONM. In both instances the patients displayed no untoward effects from TES, and post-operatively both CIs were intact and functioning as they were prior to surgery.
-
J Clin Monit Comput · Aug 2016
Randomized Controlled TrialThe relationship between the Bispectral Index (BIS) and the Observer Alertness of Sedation Scale (OASS) scores during propofol sedation with and without ketamine: a randomized, double blinded, placebo controlled clinical trial.
Prior studies have examined the static effect of intravenous ketamine on the BIS Index for sedation but it remains unknown if the BIS Index is a reliable method to track sedation levels in the presence of ketamine. The major objective of the current investigation was to compare the BIS Vista Index ability to track varying depths of sedation as determined by OASS scores in a standardized anesthetic regimen with and without ketamine. The study was a randomized, double blinded clinical trial. ⋯ There was no difference in the odds for BIS values to predict deep sedation between groups (P = 0.14). The BIS monitor can be used to monitor sedation level even when ketamine is used with propofol as part of the sedation regimen. However, ketamine reduces the value of the BIS in predicting moderate sedation levels.
-
J Clin Monit Comput · Aug 2016
Comparative StudyContinuous noninvasive cardiac output determination using the CNAP system: evaluation of a cardiac output algorithm for the analysis of volume clamp method-derived pulse contour.
The CNAP system (CNSystems Medizintechnik AG, Graz, Austria) provides noninvasive continuous arterial pressure measurements by using the volume clamp method. Recently, an algorithm for the determination of cardiac output by pulse contour analysis of the arterial waveform recorded with the CNAP system became available. We evaluated the agreement of the continuous noninvasive cardiac output (CNCO) measurements by CNAP in comparison with cardiac output measurements invasively obtained using transpulmonary thermodilution (TDCO). ⋯ This pilot analysis shows that CNCO determination is feasible in critically ill patients. A percentage error of 25 % indicates acceptable agreement between CNCO-cal and TDCO. The mean difference, the standard deviation, and the percentage error between CNCO-auto and TDCO were higher than between CNCO-cal and TDCO. A hyperdynamic cardiocirculatory state in a substantial number of patients and the hemodynamic stability making trending analysis impossible are main limitations of our study.
-
J Clin Monit Comput · Aug 2016
Observational StudyThe prevalence of long QT interval in post-operative intensive care unit patients.
The severity of patient illnesses and medication complexity in post-operative critically ill patients increase the risk for a prolonged QT interval. We determined the prevalence of prolonged QTc in surgical intensive care unit (SICU) patients. We performed a prospective cross-sectional study over a 15-month period at a major academic center. ⋯ None of the patients developed a lethal arrhythmia in the ICU. Prolonged QTc is common among post-operative SICU patients (67 %), however lethal arrhythmias are uncommon. The operative experience increases the risk for long QTc.
-
J Clin Monit Comput · Aug 2016
Comparative StudyComparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output.
A novel algorithm of impedance cardiography referred to as electrical velocimetry (EV) has been introduced for non-invasive determination of cardiac output (CO). Previous validation studies yielded diverging results and no comparison with the non-invasive gold standard cardiac magnetic resonance imaging (CMR) has been performed. We therefore aimed to prospectively assess the accuracy and reproducibility of EV compared to CMR. 152 consecutive stable patients undergoing CMR were enrolled. ⋯ Gender, height and increasing CO and SV were associated with increased bias while not affecting reproducibility. Therefore, absolute values should not be used interchangeably in clinical routine. EV yet may find its place for clinical application with further investigation on its trending ability pending.