Journal of clinical monitoring and computing
-
J Clin Monit Comput · Feb 2017
ReviewJournal of Clinical Monitoring and Computing 2016 end of year summary: cardiovascular and hemodynamic monitoring.
The assessment and optimization of cardiovascular and hemodynamic variables is a mainstay of patient management in the care for critically ill patients in the intensive care unit (ICU) or the operating room (OR). It is, therefore, of outstanding importance to meticulously validate technologies for hemodynamic monitoring and to study their applicability in clinical practice and, finally, their impact on treatment decisions and on patient outcome. In this regard, the Journal of Clinical Monitoring and Computing (JCMC) is an ideal platform for publishing research in the field of cardiovascular and hemodynamic monitoring. In this review, we highlight papers published last year in the JCMC in order to summarize and discuss recent developments in this research area.
-
J Clin Monit Comput · Feb 2017
Randomized Controlled TrialPassive continuous positive airway pressure ventilation during cardiopulmonary resuscitation: a randomized cross-over manikin simulation study.
While controlled ventilation is most frequently used during cardiopulmonary resuscitation (CPR), the application of continuous positive airway pressure (CPAP) and passive ventilation of the lung synchronously with chest compressions and decompressions might represent a promising alternative approach. One benefit of CPAP during CPR is the reduction of peak airway pressures and therefore a potential enhancement in haemodynamics. We therefore evaluated the tidal volumes and airway pressures achieved during CPAP-CPR. ⋯ High peak airway pressures are known to limit the applicability of ventilation via facemask or via supraglottic airway devices and may adversely affect haemodynamics. Hence, the application of ventilators generating high tidal volumes with low peak airway pressures appears desirable during CPAP-CPR. The limited CPAP-CPR capabilities of transport ventilators in our study might be prerequisite for future developments of transport ventilators.
-
J Clin Monit Comput · Feb 2017
Impact of advanced monitoring variables on intraoperative clinical decision-making: an international survey.
To assess the relationship between the addition of advanced monitoring variables and changes in clinical decision-making. A 15-questions survey was anonymously emailed to international experts and physician members of five anesthesia societies which focused on assessing treatment decisions of clinicians during three realistic clinical scenarios measured at two distinct time points. The first is when typical case information and basic monitoring (T1) were provided, and then once again after the addition of advanced monitoring variables (T2). ⋯ Moreover, advanced monitoring data did not significantly decrease the high level of initial practice variability in physician suggested treatments (P = 0.13), in contrast to the low variability observed within the expert group (P = 0.039). Additionally, 5-10 years of practice (P < 0.0001) and a cardiovascular subspecialty (P = 0.048) were both physician characteristics associated with a higher rate of optimal therapeutic decisions. The addition of advanced variables was of limited benefit for most physicians, further indicating the need for more in depth education on the clinical value and technical understanding of such variables.
-
J Clin Monit Comput · Feb 2017
Randomized Controlled TrialIntraoperative auditory evoked potential recordings are more reliable at signal detection from different sensor sites on the forehead compared to bispectral index.
Bispectral index (BIS) and auditory evoked potential (AEP) monitoring require the attachment of forehead sensors, posing difficulties when the surgical field involves the forehead. This study analyzed the relationship between BIS values and AEP indices from different sites on the head to establish alternative sensor locations for AEP recording. Thirty patients scheduled for elective surgery under sevoflurane anesthesia were randomly assigned to the forehead, nose or mandible groups (n = 10 patients per group). ⋯ The z-transformed coefficient in the forehead group was the same as the nose group (p = 0.24) and significantly different in the mandible group (p = 0.0046). These findings suggest that AEPs can be accurately recorded from sensors placed on the nose. Nasal AEP might be useful for monitoring electrical activity in the brain during surgeries involving the forehead.
-
J Clin Monit Comput · Feb 2017
Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients.
The Masimo Radical-7 Pulse CO-Oximeter (Masimo Corp., USA) non-invasively computes hemoglobin concentration (SpHb). SpHb was compared to Co-Oximeter readings (CoOxHb) of arterial samples in surgery patients of the emergency department. Forty-six patients were enrolled. ⋯ SpHb agreed only moderately with CoOxHb values and predicted decreases of CoOxHb only if changes of SpHb ≤ 1.0 g/dl were excluded. The detection failure rate of SpHb was high. At present, additional refinements of the current technology are necessary to further improve performance of non-invasive hemoglobin measurement in the clinical setting.