Observational StudyContinuous glucose monitoring system in the operating room and intensive care unit: any difference according to measurement sites?
Given the benefit of glucose control in the perioperative period, we evaluated the accuracy and performance of the continuous glucose monitoring system (CGMS) depending on different measurement sites in the operating room (OR) and in the intensive care unit (ICU). Patients over 18 years of age scheduled for elective surgery and ICU admission were enrolled prospectively. Two CGMS sensors were inserted into the subcutaneous tissue of the proximal lateral thigh and the lateral abdomen. ⋯ The CGMS showed low accuracy compared to arterial reference values. Nevertheless, there was no difference in the accuracy of the CGMS between two measurement sites. Perioperative performance of the CGMS still needs to be improved considering relatively low successful measurement rates.
-
J Clin Monit Comput · Feb 2017
Transesophageal Doppler reliably tracks changes in cardiac output in comparison with intermittent pulmonary artery thermodilution in cardiac surgery patients.
In this study a comparison of cardiac output (CO) measurements obtained with CardioQ transesophageal Doppler (TED) and pulmonary artery catheter (PAC) thermodilution (TD) technique was done in a systematic set-up, with induced changes in preload, afterload and heart rate. Twenty-five patients completed the study. Each patient were placed in the following successive positions: (1) supine, (2) head-down tilt, (3) head-up tilt, (4) supine, (5) supine with phenylephrine administration, (6) pace heart rate 80 beats per minute (bpm), (7) pace heart rate 110 bpm. ⋯ In comparison with PAC TD, the CardioQ TED showed a low mean bias, wide limits of agreement and a larger percentage error than should be expected from the precision of the two methods. However, an acceptable trending ability was found. Thus, the CardioQ TED should not replace CO measurements done by PAC TD, but could be a valuable tool in guiding therapy.
-
J Clin Monit Comput · Feb 2017
Use of a patient completed iPad questionnaire to improve pre-operative assessment.
Developments in healthcare technology could improve patient care and reduce healthcare costs. There is a need to facilitate communication and increase efficiency in surgical pre-assessment clinics. This study aimed to develop an iPad application to deliver an electronic patient questionnaire, and to evaluate its use in the pre-assessment environment. ⋯ Use of an electronic patient questionnaire reduces consultation time delivering greater efficiency of pre-assessment nurse time. Preconceived ideas about the use of technology in older age groups are likely inaccurate and less of a barrier than previously thought. Electronic pre-assessments could be used routinely to reduce demands on healthcare facilities, improve patient care, and triage patients prior to clinic attendance.
-
Sedation in locations outside the operating room (OR) is common. Guidelines for safe patient monitoring have been updated by the American Society of Anesthesiology to include monitoring of ventilation and/or carbon dioxide (CO2). Although technologies exist to monitor these variables, the quality and/or availability of these measurements in non-OR settings is not optimal. ⋯ After sedation, the expected decrease in MV after sedation was observed in 18 of 20 patients (average -47.82 %), while an increase in ETCO2 was observed in just 10 of 20 patients (average -5.17 mm Hg). The correlation coefficient between changes in MV and ETCO2 in response to sedation administration was positive and not significant, r = 0.223. Ventilation monitoring may provide an element of safety for earlier and more reliable detection of reduced ventilation compared to a surrogate for hypoventilation, ETCO2, in patients undergoing sedation for GI procedures outside of the OR.
-
J Clin Monit Comput · Feb 2017
Assessing the effect of preoperative levosimendan on renal function in patients with right ventricular dysfunction.
The Acute Kidney Injury Network (AKIN) classification considers SCr values, urea and urine output in order to improve timely diagnose ARF and improve patient prognosis by early treatment. Preoperative levosimendan is a new way for cardiac and kidney protection, we try to evaluate this drug in fifteen patients comparing values of AKIN scale parameters pre and post cardiac surgery in patients with right ventricle dysfunction.