Influence of the marvelous™ three-way stopcock on the natural frequency and damping coefficient in blood pressure transducer kits.
Two types of Planecta™ ports are commonly used as sampling ports in blood pressure transducer kits: a flat-type port (FTP) and a port with a three-way stopcock (PTS). Recently, a new type of three-way stopcock (Marvelous™) has been released as a Planecta™ counterpart, but its effects on the frequency characteristics and reliability of blood pressure monitoring have not been investigated. We assessed the influence of the Marvelous™ stopcock on the frequency characteristics of the pressure transducer kit. ⋯ Plotting the data on a Gardner chart revealed that the changes fell within the adequate dynamic response region, indicating they were within the allowable range. Insertion of Marvelous™ stopcocks slightly affects the natural frequency of the pressure transducer kit, similar to inserting a PTS. The results indicate that the Marvelous™ stopcock is useful for accurate monitoring of arterial blood pressure, and may be recommended when insertion of two or more closed-loop blood sampling systems is necessary.
-
J Clin Monit Comput · Feb 2018
Observational StudyInvestigation of optical neuro-monitoring technique for detection of maintenance and emergence states during general anesthesia.
The American Society of Anesthesiologist recommends peripheral physiological monitoring during general anesthesia, which offers no information regarding the effects of anesthetics on the brain. Since no "gold standard" method exists for this evaluation, such a technique is needed to ensure patient comfort, procedure quality and safety. In this study we investigated functional near infrared spectroscopy (fNIRS) as possible monitor of anesthetic effects on the prefrontal cortex. ⋯ We observed that during maintenance the signal is relatively more stable than during emergence. Maintenance and emergence states were classified with 94.7% accuracy with a non-linear model using the locally derived mean total hemoglobin, standard deviation of HbO2, minimum and range of HbO2 and HHb as features. These features were found to be correlated with the effects of sevoflurane and to carry information that allows real time and automatic classification of the anesthetized state with high accuracy.
-
J Clin Monit Comput · Feb 2018
Endotracheal bioimpedance cardiography improves immediate postoperative outcome: a case-control study in off-pump coronary surgery.
The feasibility and clinical utility of the endotracheal cardiac output monitor (ECOM) to optimize intraoperative hemodynamics and improve short-term outcome in off-pump coronary artery bypass grafting (OPCAB) is unknown. We aimed to compare ECOM with a standard of care in that specific surgical setting. Twenty consecutive adult ECOM-monitored patients undergoing OPCAB were prospectively included (ECOM group) and retrospectively compared to 42 patients scheduled for similar surgery without ECOM monitoring (Control group). ⋯ The time to extubation, the length of stay in ICU, and both troponin level at admission and lactate level at H6 were all significantly decreased in the ECOM group. On a scale ranging from 0 to 5, convenience and satisfaction regarding ECOM were 4.30 ± 1.17 and 3.45 ± 0.68, respectively. The systematic use of ECOM is associated with a significant reduction in the rate of admission to the ICU and an improvement in immediate outcome in OPCAB.
-
J Clin Monit Comput · Feb 2018
Influences of environmental noise level and respiration rate on the accuracy of acoustic respiration rate monitoring.
We tested the hypothesis that the environmental noise generated by a forced-air warming system reduces the monitoring accuracy of acoustic respiration rate (RRa). Noise levels were adjusted to 45-55, 56-65, 66-75, and 76-85 dB. Healthy participants breathed at set respiration rates (RRset) of 6, 12, and 30/min. ⋯ The RRa of one, nine, and nine participants at 76-85 dB noise agreed with RRset of 6, 12, and 30/min, respectively, which was significantly less than the other noise levels (P < 0.05). Overall, 72.9% of alarm displays highlighted incorrect values of RRa. In a noisy situation involving the operation of a forced-air warming system, the acoustic respiration monitoring should be used carefully especially in patients with a low respiration rate.
-
J Clin Monit Comput · Feb 2018
ADARRI: a novel method to detect spurious R-peaks in the electrocardiogram for heart rate variability analysis in the intensive care unit.
We developed a simple and fully automated method for detecting artifacts in the R-R interval (RRI) time series of the ECG that is tailored to the intensive care unit (ICU) setting. From ECG recordings of 50 adult ICU-subjects we selected 60 epochs with valid R-peak detections and 60 epochs containing artifacts leading to missed or false positive R-peak detections. Next, we calculated the absolute value of the difference between two adjacent RRIs (adRRI), and obtained the empirical probability distributions of adRRI values for valid R-peaks and artifacts. ⋯ Our method showed superior performance for detecting artifacts with sensitivity 100%, specificity 99%, precision 99%, positive likelihood ratio of 100 and negative likelihood ratio <0.001 compared to Berntson's and Clifford's method with a sensitivity, specificity, precision and positive and negative likelihood ratio of 99%, 78%, 82%, 4.5, 0.013 for Berntson's method and 55%, 98%, 96%, 27.5, 0.460 for Clifford's method, respectively. A novel algorithm using a patient-independent threshold derived from the distribution of adRRI values in ICU ECG data identifies artifacts accurately, and outperforms two other methods in common use. Furthermore, the threshold was calculated based on real data from critically ill patients and the algorithm is easy to implement.