Closed-loop vasopressor control: in-silico study of robustness against pharmacodynamic variability.
Initial feasibility of a novel closed-loop controller created by our group for closed-loop control of vasopressor infusions has been previously described. In clinical practice, vasopressor potency may be affected by a variety of factors including other pharmacologic agents, organ dysfunction, and vasoplegic states. The purpose of this study was therefore to evaluate the effectiveness of our controller in the face of large variations in drug potency, where 'effective' was defined as convergence on target pressure over time. ⋯ Wobble was below 3% and divergence remained negative (i.e. the controller tended to converge towards the target over time) in all norepinephrine response levels, but at the highest response level of 10 × the value approached zero, suggesting the controller may be approaching instability. Response levels of 0.1 × and 0.2 × exhibited significantly higher time-out-of-target in the lower ranges (p < 0.001) compared to the 1 × response level as the controller was slower to correct the initial hypotension. In this simulation study, the closed-loop vasopressor controller remained effective in simulated patients exhibiting 0.1 to 10 × the expected population drug response.
-
J Clin Monit Comput · Oct 2019
Randomized Controlled Trial Comparative StudyCricoid-mental distance-based versus weight-based criteria for size selection of classic laryngeal mask airway in adults: a randomized controlled study.
The optimal size selection of laryngeal mask airway (LMA) based on body weight is not always applicable. This study was prospectively conducted to evaluate the efficacy of cricoid-mental distance-based method versus weight-based method in optimal size selection of LMA in adults. Seventy-four patients (aged from 18 to 65) undergoing ophthalmic surgery were randomly assigned into cricoid-mental (CM) distance-based group or weight-based group to select appropriate size of LMA. ⋯ The overall success rate of LMA insertion in CM distance-based group was slightly increased in comparison with the weight-based group (100% vs. 91.9%, P = 0.240). There were no significant differences in score of fiber-optic view and postoperative pharyngolaryngeal morbidity between both groups (all P > 0.05). CM distance-based criteria is an alternative choice for optimizing size selection of classic LMA in adults.