Journal of clinical monitoring and computing
-
J Clin Monit Comput · Oct 2019
Anesthesia depth monitoring using alternative placement of entropy sensors: a prospective study.
Spectral entropy is based on analysis of variations in electroencephalography and frontal electromyography, and is a safe and reliable method for anesthesia depth monitoring. However, standard frontal positioning of entropy electrodes in patients undergoing cardiac surgery is sometimes challenging. The present study aimed to compare standard entropy sensor placement with an alternative (infraorbital) site. ⋯ Sensitivity/specificity analysis revealed 98.1% sensitivity, 93.3% specificity and 97.1% test efficiency for RE, and 99.2%, 95.1% and 98.5% for SE, respectively. Infraorbital entropy sensor placement in patients undergoing cardiovascular surgery is reliable and effective. The strong positive correlation between the two methods of registration enables alternative entropy measurement when frontal placement is not possible.
-
J Clin Monit Comput · Oct 2019
Observational StudyMonitoring of pulse pressure variation using a new smartphone application (Capstesia) versus stroke volume variation using an uncalibrated pulse wave analysis monitor: a clinical decision making study during major abdominal surgery.
Pulse pressure variation (PPV) and stroke volume variation (SVV) can be used to assess fluid status in the operating room but usually require dedicated advanced hemodynamic monitors. Recently, a smartphone application (Capstesia™), which automatically calculates PPV from a picture of the invasive arterial pressure waveform from any monitor screen (PPVCAP), has been developed. The purpose of this study was to compare PPVCAP with SVV from an uncalibrated pulse wave analysis monitor (SVVPC). ⋯ PPVCAP and SVVPC would have resulted in completely opposite clinical decisions regarding fluid administration in 1% of the cases. In this clinical decision making study in patients undergoing major abdominal surgery, we observed a moderate agreement between PPVCAP and SVVPC with regard to categories used to guide fluid administration. Trial Registration: Clinical Trials.gov (NCT03137901).
-
J Clin Monit Comput · Oct 2019
Observational StudyPhotoplethysmographic characterization of vascular tone mediated changes in arterial pressure: an observational study.
To determine whether a classification based on the contour of the photoplethysmography signal (PPGc) can detect changes in systolic arterial blood pressure (SAP) and vascular tone. Episodes of normotension (SAP 90-140 mmHg), hypertension (SAP > 140 mmHg) and hypotension (SAP < 90 mmHg) were analyzed in 15 cardiac surgery patients. SAP and two surrogates of the vascular tone, systemic vascular resistance (SVR) and vascular compliance (Cvasc = stroke volume/pulse pressure) were compared with PPGc. ⋯ The PPGc misclassified 7 out of the 190 episodes, presenting good accuracy (98.4% and 97.8%), sensitivity (100% and 94.9%) and specificity (97.9% and 99.2%) for detecting episodes of hypotension and hypertension, respectively. Changes in arterial pressure and vascular tone were closely related to the proposed classification based on PPG waveform. Clinical Trial Registration NTC02854852.