Journal of clinical monitoring and computing
-
J Clin Monit Comput · Dec 2021
Comparative study of silicone membrane simulator and animal eye models for sub-Tenon's block.
To compare and assess silicone membrane-based sub-Tenon's block (STB) simulator and animal eye model (goat's eye) for practicing STB in terms of anatomical similarity and feel of texture of eye layers. The study included 34 participants (26 learners and 8 consultants) from tertiary ophthalmic centres. The participants were divided into groups A and B. ⋯ Overall, 89% participants preferred the simulator; the reasons included ease of usage, helpful warning system, absence of biological waste, and facility for repeatable training. The study validated anatomical accuracy, preference, and ability of usage of the STB simulator. For broader usage, further study involving higher number of participants is recommended.
-
J Clin Monit Comput · Dec 2021
Artifact reduction by using alternating polarity stimulus pairs in intraoperative peripheral nerve action potential recording.
Intraoperative nerve action potential (NAP) recording permits direct study of an injured nerve for functional assessment of lesions in continuity. Stimulus artifact contamination often hampers NAP recording and interferes with its interpretation. In the present study, we evaluated the artifact reduction method using alternating polarity in peripheral nerve recording. ⋯ Finally, we applied the method during nerve inching and demonstrated its usefulness in intraoperative NAP recordings as the method made the recording more resilient to short conduction distances. Thus, our findings demonstrate that this artifact reduction method can be used as a supplemental tool together with our previously described bridge grounding technique or the nonlifting nerve recording configuration to further improve intraoperative peripheral nerve recording. The method can be applied in clinical settings.
-
J Clin Monit Comput · Dec 2021
Validation of a new approach for distinguishing anesthetized from awake state in patients using directed transfer function applied to raw EEG.
We test whether a measure based on the directed transfer function (DTF) calculated from short segments of electroencephalography (EEG) time-series can be used to monitor the state of the patients also during sevoflurane anesthesia as it can for patients undergoing propofol anesthesia. We collected and analyzed 25-channel EEG from 7 patients (3 females, ages 41-56 years) undergoing surgical anesthesia with sevoflurane, and quantified the sensor space directed connectivity for every 1-s epoch using DTF. The resulting connectivity parameters were compared to corresponding parameters from our previous study (n = 8, patients anesthetized with propofol and remifentanil, but otherwise using a similar protocol). ⋯ However, the topographies were not significantly different when comparing results computed from sevoflurane and propofol data, neither in the awake nor in anesthetized state. Optimizing the algorithm for simultaneously having high sensitivity and specificity in classification yielded an accuracy of 95.1% (SE = 0.96%), with sensitivity of 98.4% (SE = 0.80%) and specificity of 94.8% (SE = 0.10%). These findings indicate that the DTF changes in a similar manner when humans undergo general anesthesia caused by two distinct anesthetic agents with different molecular mechanisms of action.