Journal of clinical monitoring and computing
-
J Clin Monit Comput · Feb 2022
Review Meta AnalysisEffectiveness of consumer-grade contactless vital signs monitors: a systematic review and meta-analysis.
The objective of this systematic review and meta-analysis was to analyze the effectiveness of contactless vital sign monitors that utilize a consumer-friendly camera versus medical grade instruments. A multiple database search was conducted from inception to September 2020. Inclusion criteria were as follows: studies that used a consumer-grade camera (smartphone/webcam) to examine contactless vital signs in adults; evaluated the non-contact device against a reference medical device; and used the participants' face for measurement. ⋯ Currently available consumer-friendly contactless monitors measure HR accurately compared to standard medical devices. More studies are needed to assess the accuracy of contactless BP and RR monitors. Implementation of contactless vital sign monitors for clinical use will require validation in a larger population, in a clinical setting, and expanded to encompass other vital signs including BP, RR, and SpO2.
-
J Clin Monit Comput · Feb 2022
ReviewThe contemporary pulmonary artery catheter. Part 2: measurements, limitations, and clinical applications.
Nowadays, the classical pulmonary artery catheter (PAC) has an almost 50-year-old history of its clinical use for hemodynamic monitoring. In recent years, the PAC evolved from a device that enabled intermittent cardiac output measurements in combination with static pressures to a monitoring tool that provides continuous data on cardiac output, oxygen supply and-demand balance, as well as right ventricular performance. ⋯ Limitations of all of these measurements are highlighted as well. We conclude that thorough understanding of measurements obtained from the PAC is the first step in successful application of the PAC in daily clinical practice.
-
J Clin Monit Comput · Feb 2022
In vitro performance evaluation of AnaConDaTM-100 and AnaConDaTM-50 compared to a circle breathing system for control and consumption of volatile anaesthetics.
To identify the better volatile anaesthetic delivery system in an intensive care setting, we compared the circle breathing system and two models of reflection systems (AnaConDa™ with a dead space of 100 ml (ACD-100) or 50 ml (ACD-50)). These systems were analysed for the parameters like wash-in, consumption, and wash-out of isoflurane and sevoflurane utilising a test lung model. The test lung was connected to a respirator (circle breathing system: Aisys CS™; ACD-100/50: Puriton Bennett 840). ⋯ Wash-out was comparable in ACD-100 and ACD-50. Wash-in and wash-out were generally quicker with the circle breathing system than in ACD-100/-50. However, consumption at 0.5 minimum alveolar concentration was comparable at flows of 0.5 and 1.0 l/min.
-
J Clin Monit Comput · Feb 2022
Randomized Controlled TrialComparison of two forced air warming systems for prevention of intraoperative hypothermia in carcinoma colon patients: a prospective randomized study.
Hypothermia is common occurrence in patients undergoing colonic surgeries. We hypothesized that the underbody forced air warming blankets will be better than conventional over-body forced air warming blankets for prevention of hypothermia during laparoscopic colon surgeries. After ethics approval, sixty patients undergoing elective laparoscopic colon surgeries were randomly divided into two groups to receive warming by underbody forced air warming blanket (n = 30) or over-body forced air warming blanket (n = 30). ⋯ Underbody and over-body blankets were comparably effective in preventing hypothermia in patients undergoing laparoscopic colorectal surgery under general anaesthesia. Trial registration CTRI (2019/06/019,576). Date of Registration: June 2019, Prospectively registered.
-
J Clin Monit Comput · Feb 2022
Assessment of a new volumetric capnography-derived parameter to reflect compression quality and to predict return of spontaneous circulation during cardiopulmonary resuscitation in a porcine model.
We aimed to evaluate a volumetric capnography (Vcap)-derived parameter, the volume of CO2 eliminated per minute and per kg body weight (VCO2/kg), as an indicator of the quality of chest compression (CC) and to predict the return to spontaneous circulation (ROSC) under stable ventilation status. Twelve male domestic pigs were utilized for the randomized crossover study. After 4 min of untreated ventricular fibrillation (VF), mechanical cardiopulmonary resuscitation and ventilation were administered. ⋯ PetCO2 and VCO2/kg have similar capabilities for discriminating survivors from non-survivors, and the area under the curve for both was 0.97. VCO2/kg had similar performance as PetCO2 in reflecting the quality of CC and prediction of achieving ROSC under stable ventilation status in a porcine model of VF-related cardiac arrest. However, VCO2/kg requires a longer time to achieve a stable state after adjusting for quality of CC than PetCO2.