Observational StudyNormative values for SedLine-based processed electroencephalography parameters in awake volunteers: a prospective observational study.
Processed electroencephalography (pEEG) is used to monitor depth of anaesthesia and/or sedation. A novel device (SedLine®) has been recently introduced into clinical practice. However, there are no published data on baseline SedLine values for awake adult subjects. ⋯ There was a significant positive correlation between EMG and PSI with eyes closed (p = 0.01) but not with eyes open, which was confirmed with linear regression analysis (p = 0.01). In awake volunteers, keeping eyes open induces significant changes to SedLine-derived parameters, most likely due to increased EMG activity (e.g. eye blinking). These findings have implications for the clinical interpretation of PSI parameters and for the planning of future research.
-
J Clin Monit Comput · Dec 2021
Randomized Controlled TrialA beat-by-beat cardiovascular index, CARDEAN, to titrate opioid administration in the setting of orthopaedic surgery: a prospective randomized trial.
To determine whether a beat-by-beat cardiovascular index (CARDEAN: cardiovascular depth of analgesia, Alpha-2 Ltd, Lyon, France) reduces the incidence of tachycardia in ASA I-III patients undergoing orthopaedic surgery. A total of 76 patients were prospectively randomized into (1) a control group or (2) the CARDEAN group, in which the nurse anaesthetist was blinded to CARDEAN application. In addition to conventional signs, an external observer instructed the nurse anaesthetist to administer sufentanil 0.1 µg kg-1 when the CARDEAN crossed a threshold (≥ 60). ⋯ Data for 66 patients (27 with known hypertension) were analysed. In the CARDEAN group, (a) the dose of sufentanil was higher (control: 0.46 µg kg-1 100 min-1, CARDEAN: 0.57 µg kg-1 100 min-1, p = 0.016), (b) the incidence rates of tachycardia and untoward events were lower (respectively: - 44%; control: 2.52 events 100 min-1 [1.98-3.22]; CARDEAN: 1.42 [1.03-1.96], p = 0.005, hazard ratio: 0.56; movement, muscular contraction, or coughing: control: 0.74 events 100 min-1 [0.47-1.16]; CARDEAN: 0.31 [0.15-0.62], p = 0.038), and (c) extubation occurred more often in the operating room (control: 76.5%, CARDEAN: 97%, p = 0.016). CARDEAN-titrated opioid administration was associated with a higher dose of sufentanil, a reduction in tachycardia and earlier emergence in ASA I-III patients undergoing major orthopaedic surgery.
-
J Clin Monit Comput · Dec 2021
Simulation study on flow rate accuracy of infusion pumps in vibration conditions during emergency patient transport.
Infusion pumps are frequently used when transferring critically ill patients via patient transport cart, ambulance, or helicopter. However, the performance of various infusion pumps under these circumstances has not been explored. The aim of this study was to evaluate the flow rate accuracy of infusion pumps under various clinical vibration conditions. ⋯ However, in moderate vibration, flow rates in syringe pumps increased beyond their known error ranges, while flow rates in peristaltic pumps remained stable. In extreme vibration, accidental fluid bolus occurred in syringe pumps but not in peristaltic pumps. The newly developed cylinder pump maintained stable performance and was unaffected by external vibration environments.
-
J Clin Monit Comput · Dec 2021
Are pocket sized ultrasound devices sufficient in the evaluation of lung ultrasound patterns and aeration scoring in pulmonary ICU patients?
Lung ultrasound (LUS) is a practical diagnostic tool for several lung pathologies. Pocket sized USG devices (PSUDs) are more affordable, accessible, practical, and learning to use them is easier than standard ultrasound devices (SUDs). Their capability in image quality have been found as comparable with standard USG machines. ⋯ When PSUD was compared with SUD in terms of total B2 count, and LAS in the right, left and both lung, there was an agreement without proportional bias according to Bland Altman test. There was also good inter class correlation coefficient value as greater than 0.8 and 0.7 between two physicians in terms of counting of total B1, B2, total B lines and calculating of total LAS for SUD and PSUD respectively. PSUDs is a reliable and valid method for evaluation of LUS patterns like SUDs.