Journal of clinical monitoring and computing
-
J Clin Monit Comput · May 2021
Observational StudyA pharmacokinetic-pharmacodynamic real-time display may change anesthesiologists' behavior.
We have developed a real-time graphical display that presents anesthetic pharmacology data (drug effect site concentrations (Ce) and probability of anesthetic effects including hypnosis, loss of response to tracheal intubation), improving a previous prototype. We hypothesized that the use of the display alters (1) clinical behavior of anesthesiologists (i.e., Ce of isoflurane and fentanyl at the end of anesthesia), (2) fentanyl dose during the first 30 min of recovery in the post anesthesia care unit (PACU), and that the response of clinicians to the display in terms of workload and utility is favorable. The display was evaluated in a two-group, non-randomized prospective observational study of 30 patients undergoing general anesthesia using isoflurane and fentanyl. ⋯ There was no significant difference between the groups (means ± standard deviation, P = 0.75). There were no differences in perceived workload. Use of the display does not appear to be cognitively burdensome and may change the anesthesiologist's dosing regimen.
-
J Clin Monit Comput · May 2021
Letter Case ReportsFirst, do no harm: bilateral radial artery occlusion in a COVID-19 patient.
Objective of this case report is to draw attention to a less known thrombotic complication associated with COVID-19, i.e., thrombosis of both radial arteries, with possible (long-term) consequences. ⋯ Since COVID-19 patients are at increased risk for arterial occlusion, it appears advisable to meticulously check for adequacy of collateral (hand-) perfusion, avoiding the harm of hand ischemia if interventions (e.g., catheterizations) at the radial or ulnar artery are intended.
-
Dysnatremia-either hyponatremia or hypernatremia-is frequently encountered in the clinical practice and often poses a diagnostic and therapeutic challenge for physicians. Despite their frequent occurrence, disorders of the water and sodium balance in the human body have puzzled many physicians over the years and often remain elusive for those lacking experience in their interpretation and management. ⋯ As opposed to many existing models, our model takes both input and output into account, and integrates osmolarity and tonicity. Our governing equation should be considered a means for clinicians to get a better qualitative understanding of the relationship between the plasma sodium concentration and the variables that influence it for a wide range of scenarios.
-
J Clin Monit Comput · May 2021
A mobile terminal application program was used for endotracheal tube cuff pressure measurement.
We studied the application of a mobile terminal application program in endotracheal tube (ETT) cuff pressure measurement to improve the implementation rate of scientific ETT cuff pressure measurement and to ensure that the pressure falls within the recommended range. A pre-post controlled study lasting for 18 months was undertaken in a 40-bed general intensive care unit (GICU). This included a 6-month baseline period (baseline group) and a 6-month intervention period (intervention group). ⋯ ETT cuff pressure was monitored 742 times in both the baseline group and the intervention group. A total of 56.9% of the cuff pressure measurements in the baseline group were within the recommended range, while 78.4% of measurements in the intervention group were within the recommended range, reflecting a statistically significant difference (P < 0.05). The application of the mobile terminal application program used for ETT cuff pressure measurement could improve the percentage of ETT cuff pressure measurements falling within the recommended range.
-
J Clin Monit Comput · May 2021
Clinical evaluation of stretchable and wearable inkjet-printed strain gauge sensor for respiratory rate monitoring at different measurements locations.
The respiration rate (RR) is a vital sign in physiological measurement and clinical diagnosis. RR can be measured using stretchable and wearable strain gauge sensors which detect the respiratory movements in the abdomen or thorax areas caused by volumetric changes. In different body locations, the accuracy of RR detection might differ due to different respiratory movement amplitudes. ⋯ All the 30 subjects agreed that diagonal and upper thorax positions were the most uncomfortable and most comfortable locations for measurement, respectively. The IPSG sensor could accurately detect RR at five different locations with good repeatability. Upper thorax was the most comfortable location.