LetterAnti-decubitus bed mattress may interfere with cerebrovascular pressure reactivity measures due to induced ICP and ABP cyclic peaks.
Severe traumatic brain injury (TBI) patients are monitored with continuous arterial blood pressure (ABP) and intracranial pressure (ICP). The pressure reactivity index (PRx) is a frequently used correlation coefficient between ABP and ICP to inform clinicians at the bedside about trends in global cerebrovascular pressure regulation status. We present an unexpected influence of cyclic anti-decubitus mattress inflations and deflations on invasive ICP, ABP and PRx calculations in our TBI patients. ⋯ In our database, 23% (9/39) of the patients show recurrent peaks in the monitoring signals. We hypothesize that these peaks are caused by (a combination) of hydrostatic change, local (cervical) compression and/or incorrect sensor zeroing due to positional changes induced by the anti-decubitus mattress. This warrants further investigation by the manufacturer and exploration of data filters.
-
J Clin Monit Comput · Apr 2021
Ocular blood flow by laser speckle flowgraphy to detect cerebral ischemia during carotid endarterectomy.
Laser speckle flowgraphy (LSFG) is a noninvasive technique that can measure relative blood flow velocity in the optic fundus contributed by the ophthalmic artery, the main first branch originating from the internal carotid artery (ICA). The aim of this study was to assess the feasibility of ocular blood flow measurement by LSFG to detect ischemic stress due to carotid clamping during carotid endarterectomy (CEA). Nineteen patients undergoing CEA with ocular blood flow measurement by LSFG and intraoperative monitoring (IOM) were prospectively enrolled between August 2016 and March 2019. ⋯ The MBR reduction ratio was positively correlated with the rSO2 index (r = 0.694, 95% confidence interval: 0.336-0.877, p = 0.001). The MBR reduction ratio of ocular blood flow by LSFG after carotid clamping was significantly correlated with the rSO2 index. The ocular blood flow by LSFG could be considered an adjunct modality for evaluating cerebral ischemic tolerance during CEA.
-
J Clin Monit Comput · Apr 2021
EditorialThe case for a 3rd generation supraglottic airway device facilitating direct vision placement.
Although 1st and 2nd generation supraglottic airway devices (SADs) have many desirable features, they are nevertheless inserted in a similar 'blind' way as their 1st generation predecessors. Clinicians mostly still rely entirely on subjective indirect assessments to estimate correct placement which supposedly ensures a tight seal. Malpositioning and potential airway compromise occurs in more than half of placements. ⋯ We do not provide technical details of such a '3rd generation' device, but rather present a theoretical analysis of its desirable properties, which are essential to overcome the remaining limitations of current 1st and 2nd generation devices. We also recommend that this further milestone improvement, i.e. ability to place the SAD accurately under direct vision, be eligible for the moniker '3rd generation'. Blind insertion of SADs should become the exception and we anticipate, as in other domains such as central venous cannulation and nerve block insertions, vision-guided placement becoming the gold standard.
-
J Clin Monit Comput · Apr 2021
Time delay of the qCON monitor and its performance during state transitions.
We investigated the performance of the qCON index regarding its time delay for sudden changes in the anesthetic level as well as to separate responsiveness from unresponsiveness during loss and return of responsiveness (LOR and ROR). For evaluation of the time delay, we replayed relevant EEG episodes to the qCON to simulate sudden changes between the states (i) awake/sedation, (ii) adequate anesthesia, or (iii) suppression. We also replayed EEG from 40 patients during LOR and ROR to evaluate the qCON's ability to separate responsiveness from unresponsiveness. ⋯ AUC was 0.63-0.90 for LOR and 0.61-0.79 for ROR. Time delay and performance during state transitions of the qCON were similar to other monitoring systems such as bispectral index. The better performance of qCON during LOR than ROR probably reflects the sudden change in EEG activity during LOR and the more heterogeneous EEG during ROR.
-
J Clin Monit Comput · Apr 2021
Real-time estimation of mean arterial blood pressure based on photoplethysmography dicrotic notch and perfusion index. A pilot study.
Hypotension during general anesthesia is associated with poor outcome. Continuous monitoring of mean blood pressure (MAP) during anesthesia is useful and needs to be reliable and minimally invasive. Conventional cuff measurements can lead to delays due to its discontinuous nature. ⋯ MAPNAA provides the best estimates with respect to brachial cuff MAP and invasive MAP. Regular calibration allows to reduce drift over time. Beat to beat estimation of MAP during general anesthesia from the PPG appears possible with an acceptable average error.