Journal of clinical monitoring and computing
-
J Clin Monit Comput · Feb 2021
Randomized Controlled TrialAssessment of the benefits of head-up preoxygenation using near-infrared spectroscopy with pulse oximetry in a swine model.
Compared with supine positioning, head-up positioning improves preoxygenation and prolongs the time to oxygen desaturation. We reevaluated benefits of head-up positioning using near-infrared spectroscopy (NIRS) with pulse oximetry in a pig model. Six pigs (mean ± SD weight: 25.3 ± 0.6 kg) were anesthetized with isoflurane and evaluated in four positions-supine, head-up, head-down, head-up to supine-just before apnea (positions' order after "supine" was randomized). ⋯ Although the TOI was not associated with the positions during normovolemia, the head-up position during hypovolemia decreased TOI from 62% ± 6% (supine) to 50% ± 9% (head-up; P = 0.0019) before preoxygenation, and it remained low during apnea. The head-up position improves preoxygenation, but repositioning to supine negates the benefits. Head-up positioning during evident hypovolemia should be avoided because the cerebral oxygenation could decrease.
-
J Clin Monit Comput · Feb 2021
Accurate end systole detection in dicrotic notch-less arterial pressure waveforms.
Identification of end systole is often necessary when studying events specific to systole or diastole, for example, models that estimate cardiac function and systolic time intervals like left ventricular ejection duration. In proximal arterial pressure waveforms, such as from the aorta, the dicrotic notch marks this transition from systole to diastole. However, distal arterial pressure measures are more common in a clinical setting, typically containing no dicrotic notch. ⋯ Systolic durations, estimated by each of the end systole estimates, are then compared to the validation systolic duration provided by the PTT based end systole point. Data comes from ten pigs, across two protocols testing the algorithms under different hemodynamic states. The resulting mean difference ± limits of agreement between measured and estimated systolic duration, of [Formula: see text] versus [Formula: see text], for the new and existing algorithms respectively, indicate the new algorithms superiority.
-
Any measurement is always afflicted with some degree of uncertainty. A correct understanding of the different types of uncertainty, their naming, and their definition is of crucial importance for an appropriate use of measuring instruments. However, in perioperative and intensive care medicine, the metrological requirements for measuring instruments are poorly defined and often used spuriously. ⋯ It is therefore the task of the scientific societies to establish the standards in their area of expertise. Adopting the same understandings and definitions among clinicians and scientists is obviously the first step. In this metrologic review (part 1), we list and explain the most important terms defined by the International Bureau of Weights and Measures regarding quantities and units, properties of measurements, devices for measurement, properties of measuring devices, and measurement standards, with specific examples from perioperative and intensive care medicine.