Journal of clinical monitoring and computing
-
J Clin Monit Comput · Oct 2018
Randomized Controlled TrialAccuracy and reliability of a subcutaneous continuous glucose monitoring device in critically ill patients.
Subcutaneous continuous glucose monitoring (CGM) may have benefits in achieving glycemic control in critically ill patients. The aim of this study was to assess the accuracy and reliability of the FreeStyle Navigator I in critically ill patients and to assess patient related factors influencing the accuracy and reliability. This study is a retrospective analysis of data from a randomized controlled trial conducted in a 20-bed mixed intensive care unit. ⋯ Furthermore, the clinical accuracy, did not meet the required standards. The reliability was satisfactory, however, in almost a quarter of the patients the realtime data display was < 95%. The accuracy was considerably and significantly lower in hyper- and hypoglycemic ranges.
-
J Clin Monit Comput · Oct 2018
Comparative Study Observational StudyVelocity-pressure loops for continuous assessment of ventricular afterload: influence of pressure measurement site.
VPloop, the graphical representation of pressure versus velocity, and its characteristic angles, GALA and β, can be used to monitor cardiac afterload during anesthesia. Ideally VPloop should be measured from pressure and velocity obtained at the same arterial location but standard of care usually provide either radial or femoral pressure waveforms. The purpose of this study was to look at the influence of arterial sites and the use of a transfer function (TF) on VPloop and its related angles. ⋯ GALA and β are underestimated when measured with a radial catheter. Using pressure waveforms from femoral locations alters VPloops, GALA and β in a smaller extend. The use of a TF on radial pressure allows to correctly plot VPloops and their characteristic angles for routine clinical use.
-
J Clin Monit Comput · Oct 2018
Comparative StudyIn vitro performance of prefilled CO2 absorbers with the Zeus®.
Low fresh gas flows (FGFs) decrease the use of anesthetic gases, but increase CO2 absorbent usage. CO2 absorbent usage remains poorly quantified. The goal of this study is to determine canister life of 8 commercially available CO2 absorbent prepacks with the Zeus®. ⋯ Canister life of prefilled CO2 absorber canisters differs between brands. The FCU0.5-FGF relationship is not linear across the entire FGF range. Canister life of prepacks of the same brand for the Zeus and Aisys differs, the exact etiology of which is probably multifactorial, and may include differences in the absolute amount of absorbent and different rebreathing characteristics of the machines.
-
J Clin Monit Comput · Oct 2018
Observational StudyValidation of simplified postoperative nausea and vomiting intensity scale in Taiwan.
This study determined whether the Simplified Postoperative Nausea and Vomiting Impact Scale (SPONVIS), could be used to predict clinically important PONV in Taiwanese. In this prospective, observational study, SPONVIS, simplified Apfel PONV Risk Scores, post-operative anti-emetic drug use, total PONV score, and 3-month recall score for PONV were recorded from Taiwanese patients who had undergone general anesthesia and surgery. With antiemetic use and 3-month recall score as validations of clinical significance, we determined whether the elements and cut-off points used in the original SPONVIS study could be used in Taiwanese patients. ⋯ The SPONVIS cut-off points 3 and 5 were statistically significant predictors of anti-emetic drug use. However, a cut-off point of 3 had a higher OR (24.08) than a cut-off of 5 (14.26) for prediction of anti-emetic drug use. SPONVIS and both construct elements (the nausea and vomiting impact scores) are useful predictors of clinically important PONV in Taiwanese.