Pulse-contour derived cardiac output measurements in morbid obesity: influence of actual, ideal and adjusted bodyweight.
The non-invasive Nexfin cardiac output (CO) monitor shows a low level of agreement with the gold standard thermodilution method in morbidly obese patients. Here we investigate whether this disagreement is related to excessive bodyweight, and can be improved when bodyweight derivatives are used instead. We performed offline analyses of cardiac output recordings of patient data previously used and partly published in an earlier study by our group. ⋯ With adjusted bodyweight, bias improved to 0.04 ± 1.4 with LOA from -2.8 to 2.9 L min. Our study shows that agreement of the Nexfin-derived with invasive CO measurements in morbidly obese patients is influenced by body weight, suggesting that Nexfin CO measurements in patients with a BMI above 35 kg/m2 should be interpreted with caution. Using adjusted body weight in the Nexfin CO-trek algorithm reduced the bias.
-
The purpose of this concept study was to investigate the possibility of automatic mean arterial pressure (MAP) regulation in a porcine heart-beating brain death (BD) model. Hemodynamic stability of BD donors is necessary for maintaining acceptable quality of donated organs for transplantation. Manual stabilization is challenging, due to the lack of vasomotor function in BD donors. ⋯ The system was able to prevent hypertension, exceeding a reference of 100 mmHg by more than 10%, during 98% of a 12 h experiment. This early work demonstrates feasibility of the investigated modelling and control synthesis approach, for the purpose of maintaining normotension in a porcine BD model. There remains a need to characterize individual variability, in order to ensure robust performance over the expected population.
-
J Clin Monit Comput · Jun 2018
Efficiency of oxygen delivery through different oxygen entrainment devices during sedation under low oxygen flow rate: a bench study.
Sedative anesthetic procedures outside the operating room may depend on cylinders as oxygen source. Cylinders have limited storage capacity and a low oxygen flow rate improves the durability. We conducted the bench study to evaluate the fraction of inspired oxygen (FiO2) in different oxygen entrainment devices under low oxygen flow rate. ⋯ In the hypoventilation group, oxygen reservoir units helped oxygen retention in local area and maintained a higher oxygen concentration. There were multiple factors lead to different oxygen fraction that we measured, such as different devices, respiratory patterns, and oxygen reservoir units. The result of our bench study provided some information for anesthesiologist to choose appropriate oxygen entrainment devices in various sedative anesthetic procedures.
-
J Clin Monit Comput · Jun 2018
Correction to: The oxygen reserve index (ORI): a new tool to monitor oxygen therapy.
In the original publication of the article, the authors have realized an error in Fig. 1. The corrected version of Fig. 1 is given below.