Reliability of thermodilution derived cardiac output with different operator characteristics.
Cardiac output (CO) is commonly measured using the thermodilution technique at the time of right heart catheterisation (RHC). However inter-operator variability, and the operator characteristics which may influence that, has not been quantified. Therefore, this study aimed to assess inter-operator variability with the thermodilution technique using a mock circulation loop (MCL) with calibrated flow sensors. ⋯ The difference between MCL and thermodilution derived CO declined significantly with increasing RHC experience (P < 0.001), increasing body mass index (P < 0.001) and decreasing grip strength (P = 0.033). This study demonstrated that the thermodilution technique is a reasonable method to determine CO, and that operator experience was the only participant characteristic related to CO measurement accuracy. Our results suggest that adequate exposure to, and training in, the thermodilution technique is required for clinicians who perform RHC.
-
J Clin Monit Comput · Apr 2018
Observational StudyRespiratory variation in peak aortic velocity accurately predicts fluid responsiveness in children undergoing neurosurgery under general anesthesia.
The determination of fluid responsiveness in the critically ill child is of vital importance, more so as fluid overload becomes increasingly associated with worse outcomes. Dynamic markers of volume responsiveness have shown some promise in the pediatric population, but more research is needed before they can be adopted for widespread use. Our aim was to investigate effectiveness of respiratory variation in peak aortic velocity and pulse pressure variation to predict fluid responsiveness, and determine their optimal cutoff values. ⋯ PPV failed to demonstrate utility in this patient population. Respiratory variation in peak aortic velocity is a promising marker for optimization of perioperative fluid therapy in the pediatric population and can be accurately measured using bedside ultrasonography. More research is needed to evaluate the lack of effectiveness of pulse pressure variation for this purpose.
-
J Clin Monit Comput · Apr 2018
ReviewJournal of Clinical Monitoring and Computing 2017 end of year summary: respiration.
This paper reviews 32 papers or commentaries published in Journal of Clinical Monitoring and Computing in 2016, within the field of respiration. Papers were published covering airway management, ventilation and respiratory rate monitoring, lung mechanics and gas exchange monitoring, in vitro monitoring of lung mechanics, CO2 monitoring, and respiratory and metabolic monitoring techniques.
-
J Clin Monit Comput · Apr 2018
Real-time evaluation of an image analysis system for monitoring surgical hemoglobin loss.
Monitoring blood loss is important for management of surgical patients. This study reviews a device (Triton) that uses computer analysis of a photograph to estimate hemoglobin (Hb) mass present on surgical sponges. The device essentially does what a clinician does when trying to make a visual estimation of blood loss by looking at a sponge, albeit with less subjective variation. ⋯ The limits of agreement remained narrow and increased proportionally from the beginning to the end of the cases, reaching a maximum range of -15.3 to 22.7 g. The median (IQR) difference of EBL derived from the Triton system, gravimetric method and visual estimation versus the reference value were 13 (74), 389 (287), and 4 (230) mL, respectively. Use of the Triton system to measure Hb loss in real-time during surgery is feasible and accurate.
-
J Clin Monit Comput · Apr 2018
Low pre-operative heart rate variability and complexity are associated with hypotension after anesthesia induction in major abdominal surgery.
Significant hypotension after induction of general anesthesia is common and has the potential for serious complications. This study aimed to determine if pre-operative heart rate variability (HRV) was associated with post-induction hypotension in patients undergoing major abdominal surgery. Patients undergoing semi-elective major abdominal surgery were consecutively recruited during pre-admission clinic assessment. ⋯ Patients who experienced hypotension after general anesthesia induction had significantly lower pre-operative HRV (SDNN 16 vs. 37 ms, p < 0.001), reduced spectral power (total power 262 vs. 1236 ms2, p = 0.002) and reduced correlation dimension, a measure of signal complexity (0.11 vs. 2.13, p < 0.001). Hypotension occurred relatively frequently in our cohort and was associated with a higher ASA grade (36 vs. 6% ASA 3, p = 0.036), hence post-induction hypotension and lower HRV may be associated with severity of illness or poor physiological reserve. Pre-operative HRV was a useful screening tool in identifying patients undergoing major abdominal surgery who were at risk of haemodynamic instability after anesthesia induction.