ReviewUltrasonography in the preoperative difficult airway assessment.
To evaluate the utility of ultrasound for detection of the difficult intubation in a preoperative setting. PubMed, Ovid, CINAHL Plus Full Text, and Google Scholar searches using ["difficult airway" OR "difficult intubation" OR "difficult laryngoscopy" OR "difficult ventilation"] AND [ultrasonography OR sonography OR ultrasound] without date limitations. Abstracts without publications, case reports, letters, textbooks, unrelated topics, or foreign language articles were excluded. ⋯ Significance for sonographic prediction of difficult laryngoscopy occurred at three locations: hyomental distance [52.6 ± 5.8 mm (p < 0.01)], anterior tissue at the hyoid bone [16.9 mm (95 % CI 11.9-21.9) and 15.9 ± 2.7 mm (p < 0.0001)], and the thyrohyoid membrane [34.7 mm (95 % CI 28.8-40.7) and 23.9 ± 3.4 mm (p < 0.0001) and 28.25 ± 4.43 mm (p < 0.001)]. The vocal cords and sternal notch levels have conflicting significance. Limitations include the heterogeneous populations and lack of standard scanning protocols.
-
J Clin Monit Comput · Jun 2017
Comparative Study Observational StudyEffect of patent ductus arteriosus and patent foramen ovale on left ventricular stroke volume measurement by electrical velocimetry in comparison to transthoracic echocardiography in neonates.
This prospective single-center observational study compared impedance cardiography [electrical velocimetry (EV)] with transthoracic echocardiography (TTE, based on trans-aortic flow) and analyzed the influence of physiological shunts, such as patent ductus arteriosus (PDA) or patent foramen ovale (PFO), on measurement accuracy. Two hundred and ninety-one triplicate simultaneous paired left ventricular stroke volume (LVSV) measurements by EV (LVSVEV) and TTE (LVSVTTE) in 99 spontaneously breathing neonates (mean weight 3270 g; range 1227-4600 g) were included. For the whole cohort, the mean absolute LVSVEVwas 5.5 mL, mean LVSVTTEwas 4.9 mL, resulting in an absolute Bland-Altman bias of -0.7 mL (limits of agreement LOA -3.0 to 1.7 mL), relative bias -12.8 %; mean percentage error MPE 44.9 %; true precision TPEV33.4 % (n = 99 aggregated data points). ⋯ In neonates with shunts (PDA and/or PFO; n = 67): mean LVSVEV5.8 mL, mean LVSVTTE5.0 mL, bias -0.8 mL (LOA -3.1 to 1.5 mL), relative bias -14.8 %, MPE 41.9 %, TPEV29.3 %. Accuracy was affected by PDA and/or PFO, with a significant increase in the relative difference in LVSVEVversus LVSVTTE: Subjects without shunts -2.9 % (n = 91), PFO alone -9.6 % (n = 125), PDA alone -14.0 % (n = 12), and PDA and PFO -18.5 % (n = 63). Physiological shunts (PDA and/or PFO) in neonates affect measurement accuracy and cause overestimation of LVSVEVcompared with LVSVTTE.
-
J Clin Monit Comput · Jun 2017
Effect of delirium motoric subtypes on administrative documentation of delirium in the surgical intensive care unit.
This study compares the proportions of surgical intensive care unit (ICU) patients with delirium detected using the Confusion Assessment Method for the ICU (CAM-ICU) who received administrative documentation for delirium using International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes, stratified by delirium motoric subtypes. This retrospective cohort study was conducted at a surgical ICU from 06/2012 to 05/2013. Delirium was assessed twice daily and was defined as having ≥1 positive CAM-ICU rating. ⋯ The sensitivity and specificity of ICD-9-CM codes for delirium were 36 and 95 %. ICD-9-CM codes for delirium were available for 42 % (95 % CI 35-48 %; 105/253) of patients with hyperactive/mixed delirium and 27 % (95 % CI 20-34 %; 46/170) of patients with hypoactive delirium (relative risk = 1.5; 95 % CI 1.2-2.0; p = 0.002). ICD-9-CM codes yielded a low sensitivity for identifying patients with CAM-ICU positive delirium and were more likely to identify hyperactive/mixed delirium compared with hypoactive delirium.
-
J Clin Monit Comput · Jun 2017
Clinical TrialEfficacy of bioelectrical impedance analysis during the perioperative period in children.
We evaluated the efficacy of bioelectrical impedance analysis (BIA) during the perioperative period by estimating the preoperative and postoperative body fluid status. After obtaining informed consent, we enrolled 100 children (3-12 years of age) scheduled for elective surgeries. All children had been fasted preoperatively. ⋯ The baseline and postoperative ICW showed a strong positive correlation (Pearson correlation coefficient = 0.992, P < 0.001), as did the baseline and postoperative ECW (Pearson correlation coefficient = 0.990, P < 0.001). Also there was no dehydration and irritability on medical recording preoperatively. BIA may be an alternative method for estimating the perioperative fluid status in children and determining details of fluid administration.
-
J Clin Monit Comput · Jun 2017
Comparative StudyComputerised respiratory sounds can differentiate smokers and non-smokers.
Cigarette smoking is often associated with the development of several respiratory diseases however, if diagnosed early, the changes in the lung tissue caused by smoking may be reversible. Computerised respiratory sounds have shown to be sensitive to detect changes within the lung tissue before any other measure, however it is unknown if it is able to detect changes in the lungs of healthy smokers. This study investigated the differences between computerised respiratory sounds of healthy smokers and non-smokers. ⋯ Significant differences between computerised respiratory sounds of smokers and non-smokers have been found. Changes in respiratory sounds are often the earliest sign of disease. Thus, computerised respiratory sounds might be a promising measure to early detect smoking related respiratory diseases.