Journal of clinical monitoring and computing
-
J Clin Monit Comput · Apr 2017
Randomized Controlled Trial Observational StudyPerioperative risk factors and cumulative duration of "triple-low" state associated with worse 30-day mortality of cardiac valvular surgery.
Hospital stay and mortality in high-risk patients after noncardiac surgery has been associated with a triple low anesthesia. However, the association between anesthesia-related factors and perioperative outcome after cardiac surgery remains unclear. We tested the effect of a novel triple low state: low mean arterial pressure (MAP) <65 mmHg and low bispectral index (BIS) <45 during a low target effect-site concentration (Ce) <1.5 μg ml-1 of propofol anesthesia on postoperative duration of hospitalization and 30-day mortality in cardiac valvular patients. ⋯ Compared to a triple-low duration of <15 min, a duration >60 min increased the 30-day mortality rate by 8 times. After adjusting for patient- and procedure-related characteristics, the cumulative duration of a triple-low state (intraoperative low MAP, low BIS, and low Ce) was associated with poorer 30-day mortality, but not with prolonged duration of hospital stay. The mortality risk was even greater when a cumulative time >60 min.
-
J Clin Monit Comput · Apr 2017
Randomized Controlled TrialSugammadex at both high and low doses does not affect the depth of anesthesia or hemodynamics: a randomized double blind trial.
Previous studies have shown that sugammadex decreases the anesthetic depth when administered to reverse the neuromuscular blockade produced by rocuronium/vecuronium. The aim of the present study was to investigate the effect of sugammadex alone on anesthetic depth and hemodynamics. Sixty patients scheduled for abdominal surgery participated in the study. ⋯ Also, the secondary endpoints, namely RE, BIS, SAP and DAP, HR and SpO2 did not differ between the three groups. Comparisons between Group-2 versus Group-4, Group-2 versus Group-16 and Group-4 versus Group-16 showed no differences (p > 0.05) for all the studied variables. Sugammadex alone at low, medium or high clinical doses has no effect on anesthetic depth as assessed by Entropy and BIS or on hemodynamics.
-
J Clin Monit Comput · Apr 2017
FLOW-i ventilator performance in the presence of a circle system leak.
Recently, the FLOW-i anaesthesia ventilator was developed based on the SERVO-i intensive care ventilator. The aim of this study was to test the FLOW-i's tidal volume delivery in the presence of a leak in the breathing circuit. We ventilated a test lung model in volume-, pressure-, and pressure-regulated volume-controlled modes (VC, PC, and PRVC, respectively) with a FLOW-i. ⋯ Interestingly, VT did not differ appreciably from 6 to 0.3 L/min of fresh air flow among the 3 ventilatory modes. In the absence of leakage, peak inspiratory pressures were similar, while they were 35-45 % smaller in PRVC and VC than in PC mode in the presence of leaks. In conclusion, FLOW-i maintained VT (down to fresh gas flows of 0.3 L/min) to 90 % of its preset value in PC mode, which was 4-5 times greater than in VC or PRVC modes.
-
J Clin Monit Comput · Apr 2017
Hypoxic events and concomitant factors in preterm infants on non-invasive ventilation.
Automated control of inspired oxygen for newborn infants is an emerging technology, currently limited by reliance on a single input signal (oxygen saturation, SpO2). This is while other signals that may herald the onset of hypoxic events or identify spurious hypoxia are not usually utilised. We wished to assess the frequency of apnoea, loss of circuit pressure and/or motion artefact in proximity to hypoxic events in preterm infants on non-invasive ventilation. ⋯ Hypoxic events are frequently accompanied by respiratory pauses and/or motion artefact. Real-time monitoring and input of respiratory waveform may thus improve the function of automated oxygen controllers, allowing pre-emptive responses to respiratory pauses. Furthermore, use of motion-resistant oximeters and plethysmographic waveform assessment procedures will help to optimise feedback control of inspired oxygen delivery.
-
J Clin Monit Comput · Apr 2017
Optimal level of the reference transducer for central venous pressure and pulmonary artery occlusion pressure monitoring in supine, prone, and sitting position.
To guarantee accurate measurement of central venous pressure (CVP) or pulmonary artery occlusion pressure (PAOP), proper positioning of a reference transducer is a prerequisite. We investigated ideal transducer levels in supine, prone, and sitting position in adults. Chest computed tomography images of 113 patients, taken in supine or prone position were reviewed. ⋯ The ratio of the most cephalad blood level of RA and LA to the sternal length was 0.70 ± 0.10 and 0.68 ± 0.09 from the mid-sternoclavicular joint in sitting position, which corresponded to the upper border of 4th rib. Optimal CVP transducer levels are at four-fifths of the AP diameter of thorax in supine position, at a half of that in prone position, and at upper border of the 4th sternochondral joint in sitting position. PAOP transducer levels are similar in prone and sitting position, except for supine position which is at three-fifths of the AP diameter of thorax.