ReviewJournal of Clinical Monitoring and Computing 2016 end of year summary: cardiovascular and hemodynamic monitoring.
The assessment and optimization of cardiovascular and hemodynamic variables is a mainstay of patient management in the care for critically ill patients in the intensive care unit (ICU) or the operating room (OR). It is, therefore, of outstanding importance to meticulously validate technologies for hemodynamic monitoring and to study their applicability in clinical practice and, finally, their impact on treatment decisions and on patient outcome. In this regard, the Journal of Clinical Monitoring and Computing (JCMC) is an ideal platform for publishing research in the field of cardiovascular and hemodynamic monitoring. In this review, we highlight papers published last year in the JCMC in order to summarize and discuss recent developments in this research area.
-
J Clin Monit Comput · Feb 2017
ReviewJournal of clinical monitoring and computing 2016 end of year summary: anesthesia.
Clinical monitoring and computing are essential during general anesthesia. As a result it would be impossible to review all the articles published in the Journal of Clinical Monitoring and Computing that are relevant to anesthesia. We therefore will limit this summary to those articles that are uniquely related to anesthesia. The topics include: anesthesia machines; ensuring the airway; anesthetic depth; neuromuscular transmission monitoring; locoregional anesthesia; ultrasound; and pain.
-
J Clin Monit Comput · Feb 2017
Towards an optimal paradigm for intraoperative auditory nerve monitoring with auditory steady state responses.
Auditory steady state responses (ASSR) may offer an alternative to brainstem auditory evoked potentials for monitoring of the auditory nerve during surgical procedures. In the current study, we evaluated the influence of noise on ASSR characteristics in total intravenous anesthesia (TIVA). Simulated ASSR in real noise recorded during surgery under TIVA were constructed with known parameters. ⋯ Choice of parameters strongly influences detection and characteristics of ASSR. Optimal parameters enabled detection after 16 s in 45 %. Due to specific noise characteristics, modulation has a critical impact, which is currently not sufficiently recognized in ASSR studies.
-
J Clin Monit Comput · Feb 2017
ReviewReproducibility of transpulmonary thermodilution cardiac output measurements in clinical practice: a systematic review.
Measuring cardiac output (CO) is an integral part of the diagnostic and therapeutic strategy in critically ill patients. During the last decade, the single transpulmonary thermodilution (TPTD) technique was implemented in clinical practice. The purpose of this paper was to systematically review and critically assess the existing data concerning the reproducibility of CO measured using TPTD (COTPTD). ⋯ Achieving more than 3 boluses did not improve reproducibility; however, achieving less than 3 boluses significantly affects the reproducibility of this technique. The present results emphasize that TPTD is a highly reproducible technique for monitoring CO in critically ill patients, especially in the pediatric population. Our findings suggest that obtaining a mean of 3 measurements for determining CO values is recommended.