Changes in motor evoked potentials after erector spinae block in scoliosis surgery-when to take pre-incision baseline recordings?
Multimodal intraoperative neurophysiological monitoring (IONM) is highly valuable in scoliosis surgeries for monitoring spinal cord function, particularly during instrumentation. Accurate timing of baseline recordings of TcMEP and SSEP is crucial, as any changes observed during surgery and instrumentation are compared to these baseline recordings. ⋯ Remarkably, SSEPs remained unchanged during this period. These findings suggest that USG-ESPB may produce TcMEP changes, highlighting the importance of carefully considering the timing of baseline TcMEP acquisition in scoliosis surgery.
-
J Clin Monit Comput · Feb 2024
Improving case duration accuracy of orthopedic surgery using bidirectional encoder representations from Transformers (BERT) on Radiology Reports.
A major source of inefficiency in the operating room is the mismatch between scheduled versus actual surgical time. The purpose of this study was to demonstrate a proof-of-concept study for predicting case duration by applying natural language processing (NLP) and machine learning that interpret radiology reports for patients undergoing radius fracture repair. ⋯ This proof-of-concept study demonstrated the successful application of NLP and machine leaning to extract features from unstructured clinical data resulting in improved prediction accuracy for surgical case duration.
-
J Clin Monit Comput · Feb 2024
Review Meta AnalysisPerformance of closed-loop systems for intravenous drug administration: a systematic review and meta-analysis of randomised controlled trials.
Closed-loop drug delivery systems are autonomous computers able to administer medication in response to changes in physiological parameters (controlled variables). While limited evidence suggested that closed-loop systems can perform better than manual drug administration in certain settings, this technology remains a research tool with an uncertain risk/benefit profile. Our aim was comparing the performance of closed-loop systems with manual intravenous drug administration in adults. ⋯ The certainty of the evidence was low or very low for most outcomes. Automatic technology may be used to improve the hemodynamic profile during noradrenaline and vasodilators administration and reduce the duration of postanaesthetic recovery. Registration: This systematic review was registered with PROSPERO (CRD42022336950) on the 7th of June 2022.
-
J Clin Monit Comput · Feb 2024
Randomized Controlled TrialEfficacy and safety of three inflation methods of the laryngeal mask airway Ambu® Auraonce™: a randomized controlled study.
The laryngeal mask airway (LMA) is commonly used for airway management. Cuff hyperinflation has been associated with complications, poor ventilation and increased risk of gastric insufflation. This study was designed to determine the best cuff inflation method of AuraOnce™ LMA during bronchoscopy and EBUS (Endobronquial Ultrasound Bronchoscopy) procedure. ⋯ No difference between groups was found either for OLP (p = 0.53), LV (p = 0.26) and PC (p = 0.16). When a cuff manometer is not available, a partial inflation of AuraOnce™ LMA cuff using MV method allows to control intracuff pressure, with no significant changes of OLP and LV compared to RV and NV insufflation method. Registration clinical trial: NCT04769791.
-
J Clin Monit Comput · Feb 2024
Observational StudyMeasurement accuracy of a microwave doppler sensor beneath the mattress as a continuous respiratory rate monitor: a method comparison study.
Non-contact continuous respiratory rate monitoring is preferred for early detection of patient deterioration. However, this technique is under development; a gold standard respiratory monitor has not been established. Therefore, this prospective observational method comparison study aimed to compare the measurement accuracy of a non-contact continuous respiratory rate monitor, a microwave Doppler sensor positioned beneath the mattress, with that of other monitors. ⋯ The microwave Doppler sensor had a small bias but relatively low precision, similar to other devices. In CEG analyses, the risk of each monitor leading to inadequate clinical decision-making was low.