Journal of clinical monitoring and computing
-
J Clin Monit Comput · Feb 2024
Randomized Controlled TrialControl of mean arterial pressure using a closed-loop system for norepinephrine infusion in severe brain injury patients: the COMAT randomized controlled trial.
Brain injury patients require precise blood pressure (BP) management to maintain cerebral perfusion pressure (CPP) and avoid intracranial hypertension. Nurses have many tasks and norepinephrine titration has been shown to be suboptimal. This can lead to limited BP control in patients that are in critical need of cerebral perfusion optimization. ⋯ Over the four-hour study period, the mean percentage of time with MAP in target was greater in the CLV group than in the control group (95.8 ± 2.2% vs. 42.5 ± 27.0%, p < 0.001). Severe undershooting, defined as MAP < 10 mmHg of target value was lower in the CLV group (0.2 ± 0.3% vs. 7.4 ± 14.2%, p < 0.001) as was severe overshooting defined as MAP > 10 mmHg of target (0.0 ± 0.0% vs. 22.0 ± 29.0%, p < 0.001). The CLV system can maintain MAP in target better than nurses caring for severe brain injury patients.
-
J Clin Monit Comput · Feb 2024
Randomized Controlled TrialWireless patient monitoring and Efficacy Safety Score in postoperative treatment at the ward: evaluation of time consumption and usability.
To evaluate objective time consumption and how nurses perceived introducing wireless patient monitoring (WPM) and a validated score on patient quality and safety, the Efficacy Safety Score (ESS), at a mixed surgery ward. After fulfilling a randomised controlled trial combining the ESS and WPM, we addressed time consumption and conducted a questionnaire survey among nurses who participated in the study. The questionnaire appraised the nurses' evaluation of introducing these tools for postoperative management. Of 28 invited nurses, 24 responded to the questionnaire, and 92% reported the ESS and WPM-systems to increase patient safety and quality of care. 67% felt the intervention took extra time, but objective workload measurements revealed reduced time to 1/3 using ESS and WPM compared to standard manual assessment. Improved confidence when using the systems was reported by 83% and improved working situation by 75%. In a test situation to measure time consumption, the ESS and pre-attached WPM-systems require less time than the conventional standard of care, and may allow for more frequent clinical monitoring at the post-surgical ward. The combination of the ESS and the WPM systems was perceived as positive by participating nurses and further clinical development and research is warranted.
-
J Clin Monit Comput · Feb 2024
Evaluation of the venting principle to reduce start-up delays in syringe infusion pumps used for microinfusions.
Start-up delays of syringe pump assemblies can impede the timely commencement of an effective drug therapy when using microinfusions in hemodynamically unstable patients. The application of the venting principle has been proposed to eliminate start-up delays in syringe pump assemblies. However, effectively delivered infusion volumes using this strategy have so far not been measured. ⋯ This led to comparable zero drug delivery times between the two setups (p = 0.294). Start-up times as defined by the achievement of at least 90% of steady state flow rate were achieved faster with the vented setup (p < 0.0001), but this was counteracted by the increased backflow volumes. The application of the venting principle to the start-up of microinfusions does not improve the timely delivery of drugs to the patient since the faster start-up times are counteracted by higher backflow volumes when opening the three-way stopcock.
-
J Clin Monit Comput · Feb 2024
Agreement of zero-heat-flux thermometry with the oesophageal and tympanic core temperature measurement in patient receiving major surgery.
To identify and prevent perioperative hypothermia, most surgical patients require a non-invasive, accurate, convenient, and continuous core temperature method, especially for patients undergoing major surgery. This study validated the precision and accuracy of a cutaneous zero-heat-flux thermometer and its performance in detecting intraoperative hypothermia. Adults undergoing major non-cardiac surgeries with general anaesthesia were enrolled in the study. ⋯ Lin's concordance correlation coefficient was 0.90 (95%CI 0.89-0.92). The zero-heat-flux thermometry detected hypothermia with a sensitivity of 82% and a specificity of 90%. The zero-heat-flux thermometer is in good agreement with the reference core temperature based on tympanic and oesophagal temperature monitoring in patients undergoing major surgeries, and appears high performance in detecting hypothermia.
-
J Clin Monit Comput · Feb 2024
Observational StudyPredicting mortality in severe Covid-19 Pneumonia: the role of right ventricular dysfunction.
There is evidence that COVID-19 can have a clinically significant effect on the right ventricle (RV). Our objective was to enhance the efficiency of assessing RV dilation for diagnosing ACP by utilizing both linear measurements and qualitative assessment and its usefulness as an independent predictor of mortality. ⋯ An increase in the RV basal diameter and the presence of ACP measured by TTE are independent predictors of in-hospital mortality in patients with C-ARDS.