Journal of clinical monitoring and computing
-
J Clin Monit Comput · Jan 2000
ReviewAtelectasis formation during anesthesia: causes and measures to prevent it.
Pulmonary gas exchange is regularly impaired during general anaesthesia with mechanical ventilation. This results in decreased oxygenation of blood. A major cause is collapse of lung tissue (atelectasis), which can be demonstrated by computed tomography but not by conventional chest x-ray. ⋯ In summary, atelectasis is present in most humans during anaesthesia and is a major cause of impaired oxygenation. Avoiding high fractions of oxygen in inspired gas during induction and maintenance of anaesthesia may prevent formation of atelectasis. Finally, intermittent "vital capacity"-manoeuvres together with PEEP reduces the amount of atelectasis and pulmonary shunt.
-
J Clin Monit Comput · Jan 2000
Randomized Controlled Trial Clinical TrialNeonatal monitoring after maternal fentanyl analgesia in labor.
To characterize different methods of monitoring neonatal effects associated with maternal opioid analgesia. Special focus was on the static-charge-sensitive bed (SCSB), which could potentially serve as a non-invasive neonatal monitor. ⋯ Several differences were seen between the fentanyl and the control group babies. The SCSB method proved sensitive enough to find neonatal effects of maternal analgesia. Together with ECG and SpO2 monitoring, SCSB gives plentiful information on neonatal well-being in a non-invasive way. Results of this study emphasize the importance of neonatal monitoring after maternal opiate use in labor.
-
J Clin Monit Comput · Jan 2000
Clinical TrialSonic vibrational analysis provides continuous measurement of arterial properties.
We describe a new technology for measuring artery mechanical properties, called Sonic Vibrational Analysis (SVA). We utilize SVA to study the changes in radial artery smooth muscle tone caused by intravenous infusion of vasoactive agents. ⋯ The current results are consistent with previous studies of the effects of vasoactive agents on the radial artery. SVA is non-invasive, continuous, localized to a well-defined section of artery, and suitable for the collection of large volumes of time-resolved data in a laboratory or clinical setting.
-
Improving the prediction of successful ventilator weaning and extubation is a goal that all Intensivists and perioperative physicians strive for. The successful wean and extubation of ventilated patients decreases hospital length of stay and associated costs, but more importantly it also reduces patient morbidity and mortality. ⋯ We also review the non-respiratory factors affecting weaning and the role of the bedside nurse and respiratory therapist. Resolution of the pulmonary compromise and an understanding of respiratory physiology, used in conjunction with monitored indices of weaning parameters in a consistent fashion will continue to improve our success rates of ventilator weaning and extubation.
-
This study reports on the efficacy of using the anesthesia simulator to teach sedation and analgesia to nurses. This provision of sedation and analgesia to a patient is accomplished with the goal of maintaining the ability of the patient to respond purposefully to auditory or tactile stimuli. ⋯ The anesthesia simulator provides an excellent tool for teaching conscious sedation skills to hospital nurses. The participants' test performance improved following the session, and they also rated the educational experience as excellent.