Controlled Clinical TrialAgreement of somatic and renal near-infrared spectroscopy with reference blood samples during a controlled hypoxia sequence: a healthy volunteer study.
O3® Regional Oximetry (Masimo Corporation, California, USA) is validated for cerebral oximetry. We aimed to assess agreement of somatic and renal near-infrared spectroscopy with reference blood samples. ⋯ O3 regional oximetry can be used on the quadriceps and flank to monitor somatic saturation, yet has a saturation-level dependent bias. O3-derived values obtained at the flank underestimated renal reference values. Additionally, it is unlikely that the flank sensors did directly measure renal tissue.
-
J Clin Monit Comput · Jun 2023
Randomized Controlled TrialIntubation using video laryngeal mask airway SaCoVLM and laryngeal mask airway Ambu® Aura-i in anesthetized children with microtia: a randomized controlled study.
The Ambu Aura-i laryngeal mask is considered to be a device for blind intubation as well as for fiberoptic guided intubation. The novel video laryngeal airway mask SaCoVLM is a supraglottic airway device that allows intubation under direct vision. We hypothesized that success rates for device placement and tracheal intubation with the SaCoVLM would be comparable with the Ambu Aura-i mask. A prospective, randomized clinical trial was conducted from March 2021 to December 2021. ⋯ The time for removal was slower in the SaCoVLM group than in the Ambu Aura-i group (20.8 s ± 0.8 versus 14.7 s ± 6.1; p < 0.01). The airway leak pressure was higher in the SaCoVLM group than in the Ambu Aura-i group (27.0 s ± 1.0 versus 22.3 s ± 3.6; p < 0.01), and the incidence of blood staining was higher in the SaCoVLM group (16.7%). The SaCoVLM has an overall comparable performance to the Ambu Aura-i mask. However, the SaCoVLM is better relative to direct intubation without the assistance of a flexible intubation scope, which reduces the device's demand.
-
J Clin Monit Comput · Jun 2023
Evaluation of patient state index, bispectral index, and entropy during drug induced sleep endoscopy with dexmedetomidine.
Multiple electroencephalographic (EEG) monitors and their associated EEG markers have been developed to aid in assessing the level of sedation in the operating room. While many studies have assessed the response of these markers to propofol sedation and anesthetic gases, few studies have compared these markers when using dexmedetomidine, an alpha-2 agonist. Fifty-one patients underwent drug induced sleep endoscopy with dexmedetomidine sedation. ⋯ Lightening secondary to RASS score assessment is significantly captured by all three commercial EEG metrics (p < 0.001). Commercial EEG monitors can capture changes in the brain state associated with the RASS score during dexmedetomidine sedation. PSI and Entropy were highly correlated and may be better suited for assessing deeper levels of sedation.