Journal of clinical monitoring and computing
-
J Clin Monit Comput · Apr 2023
A survey on the availability, usage and perception of neuromuscular monitors in Europe.
Neuromuscular blocking agents (NMBAs) are routinely administered to patients in a multiplicity of anesthetic settings. Absence of postoperative residual neuromuscular block is widely considered an anesthetic patient safety mandate. Despite the increasing availability of a wider range of commercial quantitative neuromuscular monitors, the availability and use of neuromuscular monitoring devices is deemed to be suboptimal even in countries with above-average health system ratings. The present study aims to more precisely characterize the perceived availability, cost sensitivity and usability of neuromuscular monitoring devices within European anesthesia departments. ⋯ The availability of quantitative NMM in European operating theaters has increased in comparison with that reported in previous decades, potentially indicating increasing monitoring rates. European anesthesiologists express moderate confidence in quantitative neuromuscular monitors, along with a sentiment of adequate pricing when compared to their qualitative counterparts. Trust in quantitative monitors is marked by caution and awareness for artifactual recordings, with a consequent expectation that developments focusing on accuracy, reliability and ergonomics of neuromuscular monitors be prioritized.
-
J Clin Monit Comput · Apr 2023
Quantitative regional cerebral blood flow measurement using near-infrared spectroscopy and indocyanine green in patients undergoing superficial temporal to middle cerebral artery bypass for moyamoya disease: a novel method using a frequency filter.
Measuring regional cerebral blood flow (rCBF) after revascularization for moyamoya disease, as a type of ischemic cerebrovascular disease, is crucial. This study aims to validate our novel technology that combines near-infrared spectroscopy (NIRS) with a frequency filter to extract the arterial component. ⋯ Similar trends were observed for rCBF_S (MD, 3.98 ml/min/100 g; 95% CI, 2.30-5.67 ml/min/100 g on the diseased side; MD, 2.77 ml/min/100 g; 95% CI, 1.09-4.45 ml/min/100 g on the non-diseased side). Intraclass correlations 3 (ICC3s) between rCBF_N and rCBF_S were weak on the diseased side (ICC3, 0.25; 95% CI, -0.03-0.5; p = 0.07) and the non-diseased side (ICC3, 0.24; 95% CI, -0.05-0.5; p = 0.08). rCBF measurements based on this novel method were weakly correlated with rCBF measurements with SPECT.
-
The bedside Exhaled Drug MONitor - EDMON measures exhaled propofol in ppbv every minute based on multi-capillary column - ion mobility spectrometry (MCC-IMS). The MCC pre-separates gas samples, thereby reducing the influence of the high humidity in human breath. However, preliminary analyses identified substantial measurement deviations between dry and humid calibration standards. ⋯ EDMON measurement resolution at 100% relative humidity was 0.4 and 0.6 ppbv for standard concentrations of 3 ppbv and 41 ppbv. The influence of humidity on measurement performance was best described by a second-order polynomial function (R²≥0.99) with influence reaching a maximum at about 70% relative humidity. We conclude that EDMON measurements are strongly influenced by humidity and should therefore be corrected for sample humidity to obtain accurate estimates of exhaled propofol concentrations.
-
J Clin Monit Comput · Apr 2023
Identifying a sublingual triangle as the ideal site for assessment of sublingual microcirculation.
The sublingual mucosa is a commonly used intraoral location for identifying microcirculatory alterations using handheld vital microscopes (HVMs). The anatomic description of the sublingual cave and its related training have not been adequately introduced. The aim of this study was to introduce anatomy guided sublingual microcirculatory assessment. ⋯ The sublingual triangle identified in this study showed consistent network-based microcirculation, without interference from microcirculation associated with specialized anatomic structures. These findings suggest that the sublingual triangle, an anatomy guided location, yielded sublingual based measurements that conforms with international guidelines. IM showed higher TVD values, and future studies are needed with larger sample sizes to prove differences in microcirculatory parameters.