Journal of clinical monitoring and computing
-
J Clin Monit Comput · Aug 2022
Laboratory evaluation of performance of pulse oximeters from six different manufacturers during motion artifacts produced by Fluke 2XL SpO2 simulator.
We performed laboratory evaluation of six pulse oximeters from different manufacturers using the Fluke 2XL SpO2 simulator. The pulse oximeter probes were labeled 1 through 6 and tested using the two pre-programed preset functions of the Fluke 2XL SpO2 simulator, level 01 and level 02, for their performance in the presence of motion artifacts. The pulse oximeters were also tested at low perfusion index (PI) settings. ⋯ When probes were attached directly in the presence of motion artifacts, probes 2 and 6 performed well, whereas all other probes performed poorly. Successively lowering the PI degraded performance of probes 3, 4, and 5 at extremely low PI. It is observed that during motion and/or low PI conditions, multiple probes see deterioration in performance.
-
J Clin Monit Comput · Aug 2022
Observational StudyMonitoring postoperative lung recovery using electrical impedance tomography in post anesthesia care unit: an observational study.
With electrical impedance tomography (EIT) recruitment and de-recruitment phenomena can be quantified and monitored at bedside. The aim was to examine the feasibility of EIT with respect to monitor atelectasis formation and resolution in the post anesthesia care unit (PACU). In this observational study, 107 postoperative patients were investigated regarding the presence and recovery of atelectasis described by the EIT-derived parameters Global Inhomogeneity Index (GI Index), tidal impedance variation (TIV), and the changes in end-expiratory lung impedance (ΔEELI). ⋯ Furthermore, TIV showed a significantly lower value during the first 90 min of PACU stay as compared to the time period thereafter (p = 0.036). Our findings demonstrate that obesity has an influence on intraoperative atelectasis formation and de-recruitment during PACU stay. The application of EIT in spontaneously breathing PACU patients seems meaningful in monitoring pulmonary recovery.
-
J Clin Monit Comput · Aug 2022
The muscle evoked potential after epidural electrical stimulation of the spinal cord as a monitor for the corticospinal tract: studies by collision technique and double train stimulation.
To study if spinal motor evoked potentials (SpMEPs), muscle responses after electrical stimulation of the spinal cord, can monitor the corticospinal tract. Study 1 comprised 10 consecutive cervical or thoracic myelopathic patients. We recorded three types of muscle responses intraoperatively: (1) transcranial motor evoked potentials (TcMEPs), (2) SpMEPs and (3) SpMEPs + TcMEPs from the abductor hallucis (AH) using train stimulation. ⋯ In Study 2, the first and second train stimuli elicited almost identical SpMEPs, indicating a quick return of transmission after 50-60 ms considered characteristic of the corticospinal tract rather than the dorsal column, which would have recovered much more slowly. Of the two patients presented, one had no post-operative neurological deteriorations as anticipated by stable SpMEPs, despite otherwise insufficient IONM, and the other developed post-operative motor deficits as predicted by simultaneous reduction of TcMEPs and SpMEPs in the face of normal SEPs. Electrical stimulation of the spinal cord primarily activates the corticospinal tract to mediate SpMEPs.
-
J Clin Monit Comput · Aug 2022
Randomized Controlled TrialComparing the first-attempt tracheal intubation success of the hyperangulated McGrath® X-blade vs the Macintosh-type CMAC videolaryngoscope in patients with cervical immobilization: a two-centre randomized controlled trial.
We compared the hyperangulated McGrath X-blade with the Macintosh-type CMAC videolaryngoscope through the use of manual in-line stabilization on patients. The primary hypothesis was that the McGrath X-blade has a similar first-attempt success rate as the CMAC videolaryngoscope. 210 patients of ASA physical status I to III, aged 21 to 80 years old, undergoing general anesthesia requiring tracheal intubation were prospectively recruited into this two-centre randomized controlled trial, from June 2016 to April 2019. Patients with history of or predicted difficult airway, pre-existing dental risks, BMI > 35 kg/m2, cervical spondylosis or myelopathy, aspiration risks, patients who declined to participate or lacked the mental capacity to give consent were excluded. ⋯ Our study did not demonstrate a significant difference in efficacy between the McGrath X-blade and the CMAC videolaryngoscope. In patients with manual in-line stabilization, no anticipated airway difficulty and in the hands of experienced operators, the McGrath X-blade provided superior glottic views but conferred no advantage over the C-MAC, with a longer median time to intubation compared to the CMAC videolaryngoscope. Trial registration: Australian New Zealand Clinical Trial Registry (ACTRN12616000668404).
-
The contemporary practice of monitoring physiologic parameters in the critical care setting is based on alarm systems with high sensitivity but low specificity. A natural consequence of this approach is a massive amount of alarms, which potentially leads to fatigue in the personnel and negatively impacts the quality of care provided. The study objective is to determine the prevalence, types, and determinants of alarms in a neurological critical care unit (NCCU) prototype. ⋯ Alarms originated from electrocardiogram (34.6%), pulse oximeter (33.7%), noninvasive blood pressure monitoring (9.8%), respiratory monitoring (9.7%), intravenous fluid pumps (4.5%), ventilator (3.9%), enteral pumps (2.1%) and invasive blood pressure systems (1.7%). A noticeable diurnal variation was observed for type-A pulse oximeter, type-A and -B ECG alarms (increase during morning shifts), and type-A ventilator alarms (decrease during morning shifts). Alarms are highly prevalent in NCCUs and can correspond to an important portion of the workload.