Journal of clinical monitoring and computing
-
J Clin Monit Comput · Aug 2022
Observational StudyDynamic relative regional strain visualized by electrical impedance tomography in patients suffering from COVID-19.
Respiratory failure due to SARS-CoV-2 may progress rapidly. During the course of COVID-19, patients develop an increased respiratory drive, which may induce high mechanical strain a known risk factor for Patient Self-Inflicted Lung Injury (P-SILI). We developed a novel Electrical Impedance Tomography-based approach to visualize the Dynamic Relative Regional Strain (DRRS) in SARS-CoV-2 positive patients and compared these findings with measurements in lung healthy volunteers. ⋯ Lung ultrasound scores correlated with the number of pixels showing DRRS values above the derived threshold. Using Electrical Impedance Tomography we were able to generate, for the first time, images of DRRS which might indicate P-SILI in patients suffering from COVID-19. Trial Registration This observational study was registered 06.04.2020 in German Clinical Trials Register (DRKS00021276).
-
J Clin Monit Comput · Aug 2022
Oesophageal balloon positioning by echocardiography to guide positive pressure ventilation.
Understanding the respiratory mechanics of ARDS patients is crucial to avoid ventilator-induced lung injury (VILI), and this is much more challenging if not only lung compliance is altered but the whole compliance of the respiratory system is abnormal, as in obese patients. We face this problem daily in the ICU, and to optimize ventilation, we estimate respiratory mechanics using an oesophageal balloon. The balloon position is crucial to assess reliable values. In the present technical note, we describe the use of echocardiography to confirm the correct position of this instrument.
-
J Clin Monit Comput · Aug 2022
Vigilance: the behavioral impact of quantitative monitoring on administration and antagonism of neuromuscular blocking agents.
The aim of this study was to determine whether use of acceleromyography (1) changes dosing of neuromuscular blocking agents (NMBAs), and (2) increases the time between neostigmine administration and extubation, when compared with subjective assessment of neuromuscular blockade. ⋯ The data presented provides insight about the behavioral engineering inherent to the practice of anesthesiology. Introduction of neuromuscular blockade assessment appeared to increase provider vigilance in dosing of NMBAs-regardless of assessment method. The frequency of intraoperative monitoring (quantitative or subjective) was associated with an increased total dose of NMBA administered and decreased time interval between the last dose of neostigmine and extubation.
-
J Clin Monit Comput · Aug 2022
Correlation between brain tissue oxygen tension and regional cerebral oximetry in uninjured human brain under conditions of changing ventilation strategy.
Controversy surrounds regional cerebral oximetry (rSO2) because extracranial contamination and unmeasured changes in cerebral arterial:venous ratio confound readings. Correlation of rSO2 with brain tissue oxygen (PbrO2), a "gold standard" for cerebral oxygenation, could help resolve this controversy but PbrO2 measurement is highly invasive. This was a prospective cohort study. ⋯ From set point 1 to set point 2, PbrO2 increased from median 6.0, IQR 4.0-11.3 to median 22.5, IQR 9.8-43.6, p = 0.015; rSO2 increased from median 68.0, IQR 62.5-80.5 to median 83.0, IQR 74.0-90.0, p = 0.047. Correlation between PbrO2 and rSO2 is evident. Increasing FiO2 and PaCO2 results in significant increases in cerebral oxygenation measured by both monitors.
-
J Clin Monit Comput · Aug 2022
EditorialFeatures of new vision-incorporated third-generation video laryngeal mask airways.
Numerous studies have shown that blindly inserted supraglottic airway devices (SADs) are sub-optimally placed in 50 to 80% of all cases. Placement under direct vision has been recommended. We describe the very first two new SADs of the third generation that incorporate a videoscope with flexible tip. ⋯ This article describes the two new devices' physical characteristics, features, rationale for use, advantages and limitations in comparison to existing devices. Each of the two new devices-the Video Laryngeal Mask (VLMTM, UE Medical®) and the SafeLM® Video Laryngeal Mask System (SafeLMTM VLMS, Magill Medical Technology®) consist of two parts: (a) a disposable 2nd generation SAD with a silicone cuff and an anatomically curved tube; and (b) a reusable patient-isolated videoscope and monitoring screen, with the flexible scope located into a specially-designed, blind-end channel terminating in the bowl of the SAD, preventing the videoscope from contacting patient body fluids in the SAD bowl. Third generation placement-under-direct-vision supraglottic airway devices possess several theoretical safety and ease of use advantages which now need to be validated in clinical use.