Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
-
J Cardiovasc Magn Reson · Mar 2014
Multicenter StudySubclinical myocardial inflammation and diffuse fibrosis are common in systemic sclerosis--a clinical study using myocardial T1-mapping and extracellular volume quantification.
Systemic sclerosis (SSc) is characterised by multi-organ tissue fibrosis including the myocardium. Diffuse myocardial fibrosis can be detected non-invasively by T1 and extracellular volume (ECV) quantification, while focal myocardial inflammation and fibrosis may be detected by T2-weighted and late gadolinium enhancement (LGE), respectively, using cardiovascular magnetic resonance (CMR). We hypothesised that multiparametric CMR can detect subclinical myocardial involvement in patients with SSc. ⋯ Cardiac involvement is common in SSc even in the absence of cardiac symptoms, and includes chronic myocardial inflammation as well as focal and diffuse myocardial fibrosis. Myocardial abnormalities detected on CMR were associated with impaired strain parameters, as well as disease activity and severity in SSc patients. CMR may be useful in future in the study of treatments aimed at preventing or reducing adverse myocardial processes in SSc.
-
J Cardiovasc Magn Reson · Mar 2014
Imaging of carotid artery vessel wall edema using T2-weighted cardiovascular magnetic resonance.
Atherothrombosis remains a major health problem in the western world, and carotid atherosclerosis is an important contributor to embolic ischemic strokes. It remains a clinical challenge to identify rupture-prone atherosclerotic plaques before clinical events occur. Inflammation, endothelial injury and angiogenesis are features of vulnerable plaques and may all be associated with plaque edema. Therefore, vessel wall edema, which can be detected by 2D T2-weighted cardiovascular magnetic resonance (CMR), may be used as a dynamic marker of disease activity in the atherosclerotic plaque. However, 2D imaging is limited by low spatial resolution in the slice-select direction compared to 3D imaging techniques. We sought to investigate the ability of novel 3D techniques to detect edema induced in porcine carotid arteries by acute balloon injury compared to conventional 2D T2-weighted black-blood CMR. ⋯ The novel 3D imaging sequences VISTA and T2prep-GE perform comparably to conventional 2D T2-STIR in terms of detecting vessel wall edema. The improved spatial coverage of these 3D sequences may facilitate visualization of vessel wall edema to enable detection and monitoring of vulnerable carotid atherosclerotic plaques.