Annals of cardiac anaesthesia
-
Comparative Study
Transesophageal Echocardiography Compared to Fluoroscopy for Avalon Bicaval Dual-Lumen Cannula Positioning for Venovenous ECMO.
The Avalon elite bicaval dual-lumen cannula for single site VenoVenous Extracorporeal Membrane Oxygenation (VV ECMO) offers several advantages. Correct placement of the Avalon cannula is safe using image guidance and needs either fluoroscopy or Transesophageal echocardiography (TEE). We assessed our institutional ECMO performance, cannulation related complications, instances of cannula malposition among patients cannulated using the two imaging modalities. ⋯ Four cannulas (80%) placed under fluoroscopy required repositioning whereas one cannula (20%) placed under TEE needed repositioning. This difference was not statistically significant though (P = 0.099). TEE is the ideal imaging modality to guide Avalon elite cannula placement for VV ECMO.
-
Left ventricular assist devices (LVAD) have gained widespread use as an effective clinical therapy for patients with heart failure (INTERMACS 1-5) and are the standard of care for bridging patients to cardiac transplantation. Pre-implantation transesophageal echocardiography (TEE) allows interrogation of all cardiac structures and identifies potential problems such as intracardiac shunts, thrombi, aortic insufficiency, and right ventricular dysfunction that need palliation. ⋯ ICU monitoring with TEE guides optimal intervention and should be considered in selected patients. TEE will continue to remain vital to successful outcomes in LVAD patients.