Interv Neuroradiol
-
Case Reports Comparative Study
Microsurgical clipping and endovascular flow diversion of ruptured anterior circulation blood blister-like aneurysms.
Detection and treatment of blister-like intracranial aneurysms as a source of subarachnoid hemorrhage (SAH) can be challenging. In the past the results of both microsurgical and endovascular treatment were difficult. We present our experience with the treatment of blister-like aneurysms in the acute phase of SAH using microsurgical clipping, endovascular parent vessel occlusion or flow diversion. ⋯ Endovascular flow diversion is a viable option in the acute phase after SAH due to the rupture of a blister aneurysm. Implants with reduced thrombogenicity, obviating dual-platelet function inhibition, and flow diverters for vessel bifurcations would extend the indications for this treatment modality.
-
Comparative Study
Microsurgical clipping and endovascular treatment of middle cerebral artery aneurysms in an interdisciplinary treatment concept: Comparison of long-term results.
Treatment of middle cerebral artery (MCA) aneurysms has been historically considered as the almost exclusive domain of microsurgical clipping. This retrospective single-center study assesses whether microsurgical clipping or endovascular treatment (i.e. coiling and/or stenting) for MCA aneurysms yielded better occlusion rates and clinical outcome. ⋯ Both treatment modalities are associated with excellent clinical and radiological outcome if applied within an interdisciplinary treatment concept. Endovascular aneurysm repair appears to be an attractive treatment alternative compared to clipping with low complication rates for well-selected patients.
-
Case Reports
Unexpected occlusion of the contralateral transverse sinus after stenting for idiopathic intracranial hypertension.
A woman in her thirties with intracranial hypertension underwent stenting of the right transverse-sigmoid (TS) junction with resolution of the pressure gradient. Due to persisting symptoms at follow-up, she underwent a repeat study showing a patent right TS stent but the non-dominant left transverse sinus, patent on initial studies, was now completely occluded. According to the positive feedback loop hypothesis, stenting of the right transverse sinus should have resulted in a reduction in intracranial pressures (confirmed by post-stenting lumbar puncture), but also an increase in left transverse sinus diameter, opposed to the occlusion seen on venography. This unexpected finding can be explained by the positive feedback loop hypothesis if a revision is made accounting for intramural venous pressures as an opposing force of venous sinus stenosis, as venous outflow obstruction in the dominant venous sinus pathway provided an increased intramural venous pressure in the non-dominant sinus facilitating patency against extramural pressures.
-
Mechanical thrombectomy is a safe and effective treatment in patients with acute ischemic stroke caused by large vessel occlusions. However, in rare cases, the procedure may be challenging due to the composition of the embolus. We describe a case of a mechanical thrombectomy with the Embolus Retriever with Interlinked Cage (ERIC) device in a patient with an acute ischemic stroke due to calcified cerebral emboli in the middle cerebral artery. ⋯ After the administration of an intravenous thrombolytic agent, the patient was transferred to the angiographic suite for a mechanical thrombectomy. After failure to recanalize the vessel with manual aspiration thrombectomy, successful recanalization was achieved via mechanical thrombectomy using the ERIC device. Mechanical thrombectomy with an ERIC device can be a useful option in cases of acute ischemic stroke caused by calcified cerebral emboli.