Med Phys
-
Comparative Study
Comparison of seed loading approaches in prostate brachytherapy.
Since uniform seed loading in prostate brachytherapy can produce an intolerably high dose along the urethra, some form of peripheral loading is commonly employed. We define three variants of peripheral loading and compare them in a small, medium, and large prostate in terms of coverage of the planning target volume (PTV), homogeneity, and ability to spare critical structures of excessive dose. Modified uniform loading has at least 2/3 of the seeds occupying sites on a 1 cm cubic grid keyed to the prostate base and the posterior border of the prostate. ⋯ These regions approach within 10 mm of the rectum or urethra, so these two approaches require greater accuracy in intraoperative execution of the plan. Although each of the three planning approaches can achieve the treatment goals of adequate coverage and critical structure sparing, modified uniform loading has a more homogeneous dose distribution. This approach may be more forgiving of systematic errors in seed placement.