Ergonomics
-
This study aims to identify the causes of coordination breakdowns among control crews and to understand their coordination-behaviour patterns during emergencies in nuclear power plants (NPPs). On the basis of in-depth interviews with 18 control-crew operators, we identified 25 causes of coordination breakdown related to work processes, personnel, and situation and organisation. In addition, we observed 12 control-crew training sessions that dealt with emergencies and conducted lag-sequential analysis. ⋯ Practitioner summary: Causes of coordination breakdowns among control crews of NPPs were identified based on in-depth interviews with control-crew operators, and behavioural-pattern analysis of control crews in 12 training sessions were analysed to reveal the patterns that differentiate higher- and lower-performing teams. The findings of the study enrich our understanding of the critical factors and processes that influence the coordination effectiveness of NPP control crews. Abbreviations: NPP: nuclear power plant; RO: reactor operator; TO: turbine operator; CO: coordinator; SRO: senior reactor operator.