Indian J Orthop
-
Hip replacement following failed internal fixation (dynamic hip screw for intertrochanteric fractures) or previous hip arthroplasty presents a major surgical challenge. Proximal fitting revision stems do not achieve adequate fixation. Distal fixation with long-stemmed extensively coated cementless implants (like the Solution system) affords a suitable solution. We present our early results of 15 patients treated with extensively coated cementless revision stems. ⋯ The extensively coated cementless ('Solution') femoral stem provides a reasonable 'solution' to the deficient femur in hip revision. The proximal femoral deficiences can be relatively easily bypassed and distal fixation can be achieved with this stem. Extreme care needs to be taken to avoid fractures and penetration of the femoral shaft, which can, however, be managed by cerclage wiring. Principles of a successful outcome include preservation of the functional continuity of the abduction apparatus, care to recognize and prevent distal extension of fracture while inserting the stem (preemptive cerclage wiring) and supervised rehabilitation.