J Bone Joint Surg Br
-
J Bone Joint Surg Br · Dec 2012
The design of the acetabular component and size of the femoral head influence the risk of revision following 34 721 single-brand cemented hip replacements: a retrospective cohort study of medium-term data from a National Joint Registry.
Despite excellent results, the use of cemented total hip replacement (THR) is declining. This retrospective cohort study records survival time to revision following primary cemented THR using the most common combination of components that accounted for almost a quarter of all cemented THRs, exploring risk factors independently associated with failure. All patients with osteoarthritis who had an Exeter V40/Contemporary THR (Stryker) implanted before 31 December 2010 and recorded in the National Joint Registry for England and Wales were included in the analysis. ⋯ The overall risk of revision was independent of age, gender, American Society of Anesthesiologists grade, body mass index, surgeon volume, surgical approach, brand of cement/presence of antibiotic, femoral head material (stainless steel/alumina) and stem taper size/offset. However, the risk of revision for dislocation was significantly higher with a 'plus' offset head (HR 2.05, p = 0.003) and a hooded acetabular component (HR 2.34, p < 0.001). In summary, we found that there were significant differences in failure between different designs of acetabular component and sizes of femoral head after adjustment for a range of covariates.
-
J Bone Joint Surg Br · Dec 2012
Randomized Controlled TrialThe safety of peri-articular local anaesthetic injection for patients undergoing total knee replacement with autologous blood transfusion: a randomised trial.
Intra-operative, peri-articular injection of local anaesthesia is an increasingly popular way of controlling pain following total knee replacement. At the same time, the problems associated with allogenic blood transfusion have led to interest in alternative methods for managing blood loss after total knee replacement, including the use of auto-transfusion of fluid from the patient's surgical drain. It is safe to combine peri-articular infiltration with auto-transfusion from the drain. ⋯ However, none of the patients having femoral nerve blockade had detectable levels. None of the patients in either group had clinically relevant concentrations of local anaesthetic in their blood after re-transfusion. The evidence from this study suggests that it is safe to use peri-articular injection in combination with auto-transfusion of blood from peri-articular drains during knee replacement surgery.
-
J Bone Joint Surg Br · Dec 2012
The treatment of complex tibial shaft fractures by the Ilizarov method.
We report on the use of the Ilizarov method to treat 40 consecutive fractures of the tibial shaft (35 AO 42C fractures and five AO 42B3 fractures) in adults. There were 28 men and 12 women with a mean age of 43 years (19 to 81). The series included 19 open fractures (six Gustilo grade 3A and 13 grade 3B) and 21 closed injuries. ⋯ Minor complications included snapped wires in two patients and minor pin-site infections treated with oral antibiotics in nine patients (23%). Clinical scores were available for 32 of the 40 patients at a median of 55 months (mean 62, (26 to 99)) post-injury, with 'good' Olerud and Molander ankle scores (median 80, mean 75, (10 to 100)), 'excellent' Lysholm knee scores (median 97, mean 88, (29 to 100)), a median Tegner activity score of 4 (mean 4, (0 to 9)) (comparable to 'moderately heavy labour / cycling and jogging') and Short Form-12 scores that exceeded the mean of the population as a whole (median physical component score 55 (mean 51, (20 to 64)), median mental component score 57 (mean 53, (21 to 62)). In conclusion, the Ilizarov method is a safe and reliable way of treating complex tibial shaft fractures with a high rate of primary union.
-
We summarise and highlight the safety concerns within the field of trauma and orthopaedic surgery with particular emphasis placed on current controversies and reforms within the United Kingdom National Health Service.
-
J Bone Joint Surg Br · Dec 2012
Posterior spinal arthrodesis for adolescent idiopathic scoliosis using pedicle screw instrumentation: does a bilateral or unilateral screw technique affect surgical outcome?
We reviewed 212 consecutive patients with adolescent idiopathic scoliosis who underwent posterior spinal arthrodesis using all pedicle screw instrumentation in terms of clinical, radiological and Scoliosis Research Society (SRS)-22 outcomes. In Group 1 (51 patients), the correction was performed over two rods using bilateral segmental pedicle screws. In Group 2 (161 patients), the correction was performed over one rod using unilateral segmental pedicle screws with the second() rod providing stability of the construct through two-level screw fixation at proximal and distal ends. ⋯ The implant cost was reduced by mean 35% in Group 2 due to the lesser number of pedicle screws. Unilateral and bilateral pedicle screw techniques have both achieved excellent deformity correction in adolescent patients with idiopathic scoliosis, which was maintained at two-year follow-up. This has been associated with high patient satisfaction and low complication rates.