American journal of veterinary research
-
Cardiovascular effects and pulmonary gas exchange were compared during conventional mechanical ventilation (CMV) and interrupted high-frequency, positive-pressure ventilation (IHFPPV) in 6 anesthetized ponies in dorsal recumbency. When the peak airway pressure (Paw) was held constant at control values attained during CMV (18 to 20 cm of H2O), and the ventilator frequency of IHFPPV was varied over the range, 2.5 to 12.5 Hz, significant (P less than 0.05) changes from control values were observed only in the ratio of dead-space volume to tidal volume (VD/VT) and in the respiratory minute volume (VE). The mean (+/- SEM) carbon dioxide excretion (VCO2) was 2.12 +/- 0.1 ml/kg/min during IHFPPV. ⋯ With increasing Paw, VD/VT decreased directly with increasing Paw from 98 to 69.3%. Gas exchange at a Paw of 15 cm of H2O during IHFPPV was equivalent to conditions at Paw of 20 cm of H2O during CMV. At a higher Paw during IHFPPV, improvements over control values were observed in gas exchange.