Cir Cir
-
Randomized Controlled Trial Comparative Study Clinical Trial
[Pulmonary mechanics, oxygenation index, and alveolar ventilation in patients with two controlled ventilatory modes. A comparative crossover study].
To compare in a crossover study pulmonary mechanics, oxigenation index (PaO(2)/FiO(2)), and partial pressure of CO(2) in arterial blood (PaCO(2)) in patients with mechanical ventilation in two controlled ventilatory modes. ⋯ Peak inspiratory pressure (PIP) was higher in VC than in PC (31.5 vs 26 cm H(2)O), which resulted in a significant increase in transpulmonary pressure amplitude difference (DP) (25 vs 19 cm H(2)O). Mean airway pressure (MAP) and OI were lower in VC than in PC (11.5 vs 12 cm H(2)O, and 198.5 vs 215, respectively). Dynamic compliance (DynC) was lower in VC than in PC (20 vs 26 ml/cm H(2)O), p < 0.05 for all values. At constant ventilator settings in the same patient, PC and not VC ventilation decreases PIP (which results in smaller transpulmonary pressure amplitude difference), increases MAP, and DynC and improves the oxygenation index.