World Neurosurg
-
We investigated the indirect puncture method using a novel arc puncture-guided device in percutaneous transforaminal puncture to improve puncture accuracy and reduce the fluoroscopy, puncture, and operation times. ⋯ Indirect puncture using the novel arc puncture-guided device for percutaneous transforaminal puncture can significantly improve puncture accuracy and reduce the fluoroscopy, puncture, and operation times. Indirect puncture using the novel device in percutaneous transforaminal endoscopic discectomy is a potential and practical puncture method.
-
Tentorial dural arteriovenous fistulas (DAVFs) are a dangerous subtype of fistula. Lawton et al classified this type of fistula into 6 categories based on specific operative strategies. Clinical manifestations of 6 types of tentorial DAVFs vary to some extent. ⋯ There are anatomic communications between the perimedullary vein and cerebellar vein or veins of the brainstem. Almost all of the Cognard type V DAVFs are found in the posterior fossa. Here, we present a Cognard type V DAVF with a fistula located around the torcular herophili.