Thromb Haemostasis
-
Comparative Study
A comparative multi-laboratory assessment of three factor VIII/von Willebrand factor concentrates.
Five expert laboratories have participated in a cross-laboratory study to co-evaluate and compare three commercial Factor VIII/von Willebrand factor (VWF) concentrates. A total of nine factor concentrate lots were evaluated, comprising AHF (High Purity) (AHF HP; x3), Biostate (x3) and Humate/Haemate (x3). All laboratories blind tested for FVIII: C, VWF: Ag and VWF: CB, four tested for VWF: RCo, and one performed VWF: Multimers. ⋯ The LMW multimer band seen with AHF HP was not observed with Biostate. The defined pattern of increasing CB/ Ag from AHF HP to Humate/Haemate and Biostate was consistently observed in study data from each of the five laboratories. In conclusion, study findings indicate some differences in the retention of functional/ HMW VWF between factor concentrates, and this is expected to have significant implications in terms of clinical efficacy for therapy in VWD.