Cranio
-
Randomized Controlled Trial Clinical Trial
Better palpation of pain: reliability and validity of a new pressure pain protocol in TMD.
The purpose of this research was to employ a double-blind placebo control design of iontophoretically administered lidocaine to assess the test-retest reliability and validity of a magnitude matching procedure using a pressure algometer. In studies in the literature on assessment of pain in temporomandibular disorders (TMD), the pressure algometer has been found to be a reliable means of measuring pressure-pain threshold and a sensitive measure of treatment-response in the laboratory. However, previous research with this apparatus has not employed more sophisticated psychophysics. ⋯ Although it was hypothesized that subjects in the anesthesia group would demonstrate reduced discriminability as compared with the control groups, no differences were found among the three groups on this measure. However, differences in response bias were found, with both the placebo control and no-treatment control groups differing from the experimental group but not from each other. Possible explanations and the implications of these findings are discussed.