Journal of forensic sciences
-
Review Case Reports
Pregnancy, cesarean, and pheochromocytoma: a case report and literature review.
A 43-year-old full-term pregnant woman (gravida 2, para 1, medical history of gestational diabetes mellitus) developed a sudden and malignant hypertension with hemoptysis, sweat, and tachycardia during a scheduled C-section. A dead newborn was delivered and was successfully resuscitated. The mother died after resistant cardiac arrest. ⋯ In pregnant women, its symptoms can mimic gestational hypertension, preeclampsia or eclampsia, and gestational diabetes mellitus. The gestational diabetes mellitus was presumed to be a symptom of the pheochromocytoma, and cardiopulmonary failure the result from the necrosis of the tumor provoked by gravid uterus compression. From a medico-legal point of view, the tumor could not have been suspected during the pregnancy.
-
Comparative Study
Manual and automated cardiopulmonary resuscitation (CPR): a comparison of associated injury patterns.
The purpose of this study was to identify and compare patterns of trauma associated with AutoPulse(®) CPR and manual CPR. Finalized autopsy records from 175 decedents brought to the Harris County Institute of Forensic Sciences were reviewed, 87 received manual-only CPR, and 88 received AutoPulse(®) CPR (in combination with manual CPR as per standard protocol). ⋯ The characteristic pattern observed in AutoPulse(®) CPR use included a high frequency of posterior rib fractures, skin abrasions located along the anterolateral chest and shoulder, vertebral fractures, and a few cases of visceral injuries including liver lacerations, splenic lacerations, and hemoperitoneum. Knowledge of the AutoPulse(®) CPR injury pattern can help forensic pathologists differentiate therapeutic from inflicted injuries and therefore avoid an erroneous assessment of cause and manner of death.
-
The aim of the study is to present the application of a headspace-gas chromatography-mass spectrometry (HS-GC-MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. ⋯ The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning.