Utility of helical computed tomography in the study of arytenoid dislocation and arytenoid subluxation.
Conventional computed tomography (CT) has been considered a mainstay in the evaluation of the larynx. A major difficulty with utilizing this modality, especially in the study of the arytenoid, is the time necessary to perform a thin-slice examination through a structure that has a propensity to move with respiration and swallowing. ⋯ A comprehensive radiographic examination illustrating the cricoarytenoid relationship in all of the subjects was completed in less than 20 seconds by using axial reconstructions in 2-mm-thick slices at 1-mm intervals, with subsequently derived sagittal and coronal reconstructions. Helical CT may be a useful adjunct in the diagnosis of arytenoid subluxation or dislocation.