Blow-by, a common form of nebulizer therapy, in which the device is held away from a child's face, has been dismissed as ineffective because studies have demonstrated incremental aerosol drop-off with increasing distances from the face. Many of these studies do not take into account differences among nebulizer systems. Using common, commercially available nebulizer systems, we defined the interaction of system components (nebulizer type, face mask configuration, and compressor characteristics) on aerosol delivery with and without blow-by. ⋯ At 4 cm, the Pari system delivered more drug than Respironics at 0 cm, suggesting adequate therapy during blow-by for some systems. Our results indicate that pediatric aerosol delivery is a strong function of the nebulizer system as a whole, and not simply a function of blow-by distance from the face or nebulizer efficiency. In uncooperative children, blow-by can be an effective means of drug delivery with the appropriate nebulizer system.
-
Randomized Controlled Trial
Different tracheotomy tube diameters influence diaphragmatic effort and indices of weanability in difficult to wean patients.
To determine the effects of different tracheotomy tube sizes on diaphragm effort and weanability indices. ⋯ In tracheotomized difficult to wean subjects the decrease of the tracheotomy tube size was associated with an increased PTP(di), f/V(T), and TT(di), that were otherwise normal, using a higher diameter. The in vitro study showed that the resistances increased similarly for tracheotomy tube and endotracheal tube, decreasing the diameter and increasing the flows.
-
Randomized Controlled Trial
Evaluation of a peer-led asthma self-management program and benefits of the program for adolescent peer leaders.
Asthma is the leading chronic condition in adolescents. Nonetheless, research efforts to address adolescent asthma morbidity by applying a developmentally appropriate self-management intervention have been limited. Recently a peer-led asthma self-management program has been developed and implemented for adolescents. The purpose of the study was to assess the acceptability of a peer-led asthma program for adolescents based on participant feedback and to examine the program's impact on asthma outcomes in peer leaders. ⋯ A peer-led asthma self-management program was successfully implemented and well received by adolescent learners. Asthma outcomes in peer leaders appear to have improved as a result of the program, although caution should be exercised in determining clinical meaningfulness, given the modest changes in mean scores. ClinicalTrials.gov registration NCT01161225.
-
This was an evaluation of intra-individual variation of the cuff-leak test (ΔCLT) immediately post-intubation and pre-extubation, as a predictor of post-extubation stridor. ⋯ The intra-individual variation of CLT immediately post-intubation and pre-extubation does not improve the accuracy of a standard pre-extubation CLT to predict post-extubation stridor. Moreover, the standard pre-extubation CLT did not appear in our study to be an ideal test to detect post-extubation stridor. Larger studies should be performed before generalizing these preliminary results.
-
The accuracy of end-expiratory lung volume measurement by the modified nitrogen wash-out/wash-in method (EELV-N(2)) depends on the precise determination of carbon dioxide elimination (V(CO(2))), which is affected by alveolar dead space (V(D-alv)). The purpose of this study was to investigate the influence of V(D-alv) on EELV-N(2). ⋯ In this surfactant-depleted model, EELV measurement by the modified EELV-N(2) method reveals a systematic underestimation at high PEEP levels that is partly due to an increase in V(D-alv).