Resp Care
-
Case Reports Comparative Study
Use of an endoscopy face mask in patients with gastric distention undergoing noninvasive ventilation for acute respiratory failure: a comparative case study report.
We describe the use of an endoscopy face mask with a perforated membrane, which allows a nasogastric tube for continuous noninvasive ventilation in acute hypercapnic respiratory failure, in 2 patients who developed gastric distention. This interface was able to avoid most nonintentional leaks through the mask, as compared with a conventional approach, improving ventilation efficiency. To our knowledge, this is the first case report of an endoscopy face mask used in noninvasive ventilation for this specific side effect.
-
Noninvasive ventilation (NIV) is increasingly utilized outside the ICU for patients with acute respiratory failure. However, success and failure risk factors and patient safety aspects have been poorly explored in this setting. So far, no study has evaluated the perspective of the patient, despite the known high relevance of patient participation for NIV success. ⋯ Subjects reported a low level of involvement in the initial setting of NIV treatment, low satisfaction about communication with the caring staff, and a suboptimal safety level in case of emergency.
-
The functional role of the human diffuse panbronchiolitis critical region 1 (DPCR1) gene, located in the major histocompatibility complex class I, has not been widely investigated. However, this gene is a well known genetic marker for diffuse panbronchiolitis, a disease affecting human respiratory bronchioles. In this study we explored the association between polymorphisms in DPCR1 and aspirin-exacerbated respiratory disease (AERD), an asthma phenotype. ⋯ Our results show that polymorphisms in DPCR1 are not associated with the risk of AERD.
-
The mechanism of high-flow oxygen therapy and the pressures reached in the airway have not been defined. We hypothesized that the flow would generate a low continuous positive pressure, and that elevated flow rates in this model could produce moderate pressures. The objective of this study was to analyze the pressure generated by a high-flow oxygen therapy system in an experimental model of the pediatric airway. ⋯ According to our hypothesis, high-flow oxygen therapy systems produced a low-level CPAP in an experimental pediatric model, even with the use of very high flow rates. Linear regression analyses showed similar linear relationships between flow and pressures measured in the pharynx and in the airway. This finding suggests that, at least in part, the effects may be due to other mechanisms.
-
Despite potential benefits of intrapulmonary percussive ventilation (IPV) in various respiratory diseases, the impact of setting parameters on the mechanical effects produced by IPV in the lungs is unknown. We hypothesized that changing the parameters on IPV would modulate these effects. This in vitro study aimed at comparing the changes in intrapulmonary effects resulting from changes in parameters in 3 portable IPV devices (IMP2, Impulsator, and Pegaso). ⋯ This study suggests that changing the parameters considerably modulates the mechanical effects produced by portable IPV devices in the lungs. Increasing frequency increased PEEP and percussion, but decreased ventilation. Increasing I/E time increased PEEP and E/I flow ratio, and decreased percussion. Finally, increasing pressure increased PEEP and ventilation. The Pegaso produced the highest PEEP, least percussion, and smallest change in E/I flow ratio.