A large gap exists between the completion of clinical research demonstrating the benefit of new treatment interventions and improved patient outcomes resulting from implementation of these interventions as part of routine clinical practice. This gap clearly affects patient safety and quality of care. Knowledge translation is important for addressing this gap, but evaluation of the most appropriate and effective knowledge translation methods is still ongoing. Through describing one model for knowledge translation and an example of its implementation, insights can be gained into systematic methods for advancing the implementation of evidence-based interventions to improve safety, quality, and patient outcomes.
-
Comparative Study
Influence of nebulizer type, position, and bias flow on aerosol drug delivery in simulated pediatric and adult lung models during mechanical ventilation.
The effectiveness of aerosol drug delivery during mechanical ventilation is influenced by the patient, ventilator, and nebulizer variables. The impact of nebulizer type, position on the ventilator circuit, and bias flow on aerosol drug delivery has not been established for different age populations. ⋯ During simulated mechanical ventilation in pediatric and adult models, bias flow and nebulizer type and position impact aerosol drug delivery.
-
The effects of intermittent positive-pressure breathing (IPPB) and abdominal belt on regional lung ventilation in neuromuscular patients are unknown. We conducted a prospective physiologic short-term study in stable neuromuscular patients to determine the effects of IPBB, with and without abdominal belt, on regional lung ventilation. ⋯ In patients with neuromuscular disease, supine IPPB treatments, with or without abdominal belt, increased ventilation to anterior lungs regions, compared to the left-lateral and right-lateral positions. Global ventilation 3 hours after IPPB treatments remained higher than at baseline and was best preserved with the use of an abdominal belt.
-
The position of the jet or ultrasonic nebulizer in the ventilator circuit impacts drug delivery during mechanical ventilation, but has not been extensively explored, and no study has examined all of the commonly used nebulizers. ⋯ During mechanical ventilation the optimal drug delivery efficiency depends on the aerosol generator, the ventilator circuit, and the aerosol generator position.
-
Clinical practice guidelines recommend daily spirometer calibration checks and weekly linearity checks. The long-term stability of the volume and flow accuracy of a specific model of spirometer should be carefully characterized before modification of the frequency of calibration checks is considered for that model of spirometer. ⋯ The EasyOne retained inhalation and exhalation volume accuracy of better than 3% for at least 4 years. Routine multiple-speed volume calibration checks may not be necessary with the EasyOne. The acceptability and repeatability of patient efforts should be the primary focus of quality-assurance programs with spirometers that have been demonstrated to remain accurate for long periods.