Clin Chem Lab Med
-
Comparative Study
Salivary cortisol--an alternative to serum cortisol determinations in dynamic function tests.
Salivary cortisol was measured as an alternative to serum cortisol as a marker for adrenocortical function following insulin tolerance test, corticotropin-releasing-hormone stimulation and adreno-corticotrophic hormone stimulation. During insulin tolerance test and corticotropin-releasing-hormone stimulation adreno-corticotrophic hormone was also measured. The tests were performed on healthy control subjects as well as on patients under investigation for various disturbances in the hypothalamic-pituitary-adrenocortical axis (insulin tolerance test: 3 controls on two occasions and 14 patients; corticotropin-releasing-hormone stimulation: 4 controls and 18 patients; adreno-corticotrophic hormone stimulation: 6 controls and 10 patients). ⋯ Characteristic of the results for the insulin tolerance test was a significant initial mean decrease (p < 0.05), not found in serum, and the highest observed salivary cortisol value was delayed for at least 30 minutes compared to that in serum. Plasma adreno-corticotrophic hormone correlated significantly with the cortisol concentrations determined 15 minutes later in serum (r = 0.54-0.64) and in saliva (r = 0.76-0.85). The more pronounced cortisol response in saliva than in serum and its closer correlation with adreno-corticotrophic hormone offer advantages over serum cortisol, suggesting salivary cortisol measurement may be used as an alternative parameter in dynamic endocrine test.