Mikrobiyol Bul
-
Comparative Study
[Comparison of interferon-gamma whole blood assay with tuberculin skin test for the diagnosis of tuberculosis infection in tuberculosis contacts].
Tuberculin skin test which is used for the detection of latent tuberculosis (TB), has many disadvantages such as false positivities due to cross reactions between environmental mycobacteria and BCG strain, false negativities due to immunosuppression and malpractice, and also difficulties in application and evaluation. Recently a new diagnostic test which measures the production of interferon (IFN)-gamma in whole blood upon stimulation with specific ESAT-6 and CFP-10 antigens of Mycobacterium tuberculosis has been introduced. Since most of the mycobacteria other than tuberculosis and BCG strain do not contain these antigens, the detection of IFN-gamma levels indicates the specific T-cell response against M. tuberculosis. ⋯ Evaluation of agreement rates of the tests according to the risk groups yielded 64.6% (K = 0.3) for Group 1, 71.7% (K = 0.32) for Group 2, and 63.5% (K = 0.21) for Group 3, which all coefficients showed poor agreement. Although IFN-gamma blood assay has many advantages such as objective and quantitative results, no interference with vaccination due to the use of specific antigens and being practical, the high cost and the need for well-equipped laboratory are its disadvantages. As a result it was concluded that, IFN-gamma blood assay has limited value for the detection of latent TB infection in our country, since the prevalence of TB infection and BCG vaccination rates are high in Turkey.