J Avian Med Surg
-
To compare the bending strength of a locking plate (LP), nonlocking plate (NLP), and an external skeletal fixator intramedullary pin (ESF-IM) tie-in fixation applied by a dorsal approach in an avian humerus fracture model, 5 left humeri obtained from pigeon (Columba livia) cadavers were randomly assigned to each repair technique (n = 15). The ESF-IM group was repaired with a 0.062-inch intramedullary pin tied-in with two 0.035-inch positive profile transfixation pins using acrylic filled plastic tubing. The LP group was repaired with a dorsally applied titanium 1.6-mm screw 7-hole locking plate (1 bicortical and 2 monocortical screws in each segment). ⋯ This study demonstrated that bending biomechanical properties of the ESF-IM configuration were superior to those of the dorsal plate fixation. Exact properties of fixation required to facilitate avian fracture healing are largely unknown. Further study, including assessments of optimal plate position and configuration, and torsional and in vivo studies in avian species are warranted.